High-efficiency cleaning technology and lifespan prediction for the ceramic membrane treating secondary treated effluent.
Lv, Zongwei; Zhang, Shoubin; Jiao, Wenhai; Zuo, Xinyi; Zhang, Yuanyuan; Liu, Yutian.
Afiliação
  • Lv Z; School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China E-mail: Shoubin_Zhang@163.com.
  • Zhang S; School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China.
  • Jiao W; Jinan Municipal Engineering Design & Research Institute (Group) Co., Ltd, Jinan 250003, China.
  • Zuo X; School of Civil Engineering and Architecture, University of Jinan, Jinan 250022, China.
  • Zhang Y; Tong Yuan Design Group Co., Ltd, Jinan 250101, China.
  • Liu Y; Jinan Municipal Engineering Design & Research Institute (Group) Co., Ltd, Jinan 250003, China.
Water Sci Technol ; 88(1): 321-338, 2023 Jul.
Article em En | MEDLINE | ID: mdl-37452550
Chemical cleaning is one of the key technical means to control membrane fouling, restore membrane flux and ensure the stable operation of membrane systems. In the experiment, the six most representative chemical cleaning agents for ceramic membranes, such as sulfuric acid (H2SO4), sodium hydroxide (NaOH), sodium hypochlorite (NaClO), ethylenediaminetetraacetic acid disodium salt (EDTA-Na2), sodium dodecyl sulfate (SDS) and nonylphenol polyoxyethylene ether (OP-10), were used as research objects. The cleaning effect of the two-step combined cleaning of chemical cleaning agents on the fouled membrane was systematically investigated. Results showed that the order of the chemical cleaning agent had a significant effect on the cleaning effect. The best chemical cleaning program was determined to be NaClO first and then SDS: the fouled ceramic membrane was soaked in NaClO solution at 0.15% for 2.5 h and further soaked in SDS solution at five times its own critical micelle concentration for 2.5 h. The predicted long-term lifespan of the ceramic membranes was 4.91 years. Scanning electron microscopy-energy spectrum analysis showed that the surface roughness of the cleaned ceramic membrane was slightly higher than that of the new membrane. The contact angle was slightly lower than that of the new membrane.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Longevidade Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Longevidade Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Revista: Water Sci Technol Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de publicação: Reino Unido