Mid-term outcomes of minimally invasive infrapubic approach for inflatable penile prosthesis implantation: A single-center study and literature review.
Andrology
; 12(3): 624-632, 2024 Mar.
Article
em En
| MEDLINE
| ID: mdl-37452742
BACKGROUND: The minimally invasive infrapubic approach (MIIA) for inflatable penile prosthesis (IPP) placement has shown favorable peri-operative safety and efficacy profile, but scarce data exist on long-term follow-up. OBJECTIVES: We investigated the safety and efficacy of IPP implantation via the MIIA after a minimum 5-year follow-up. MATERIALS AND METHODS: We identified data of implanted patients prospectively included in our institutional database. Complications and functional outcomes were assessed by using validated tools. Specifically, quality of life and patient satisfaction were evaluated by the Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire. Kaplan-Meier method was used to analyze IPP survival (defined as a working IPP). RESULTS: Overall, 67 patients implanted by MIIA with a median (IQR) age of 64 years (61-70) were included. The median (IQR) follow-up duration was 71 months (63-80). Fifteen (22%) patients experienced complications: minor (Clavien ≤2) events included changes in penile sensitivity (n = 1; 1.5%), orgasmic dysfunction (n = 1; 1.5%), pain (n = 5; 7%), urinary tract infection (n = 2; 3%), and chronic discomfort (n = 1; 1.5%); major (Clavien 3) complications were represented by mechanical failure (n = 3; 4.5%), IPP infection (n = 1; 1.5%), and cylinder protrusion (n = 1; 1.5%). The estimated IPP survival was 94% (95% CI, 91.4-96.6), 92.5% (95% CI, 89.7-95.3), and 92.5% (95% CI, 89.7-95.3) at 3, 5, and 7 years after implantation, respectively. In patients using the device at follow-up (n = 61; 91%), median (IQR) scores for QoLSPP domains demonstrated favorable functional outcomes and patient satisfaction: functional 21 (19-23), personal 16 (15-18), relational 14 (12-15), and social 12 (11-14). DISCUSSION AND CONCLUSION: This study represents the longest follow-up using validated tools to assess the outcomes of IPP implantation via MIIA so far. IPP placement via MIIA confirms to be safe and to offer high satisfaction to both patients and partners at mid-term evaluation.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Prótese de Pênis
/
Implante Peniano
/
Disfunção Erétil
Tipo de estudo:
Prognostic_studies
Aspecto:
Patient_preference
Limite:
Aged
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Andrology
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Itália
País de publicação:
Reino Unido