Your browser doesn't support javascript.
loading
A dual-mode nanoprobe based on silicon nanoparticles and Fe(II)-phenanthroline for the colorimetric and fluorescence determination of nitrite.
Yang, Chunlei; Xu, Guiju; Hou, Chenghao; Peng, Lizeng; Wang, Weiting; Zhang, Hongwei; Zhang, Xiaoling.
Afiliação
  • Yang C; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China. chunlei_y@163.com.
  • Xu G; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China.
  • Hou C; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China.
  • Peng L; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China.
  • Wang W; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China.
  • Zhang H; Institute of Food & Nutrition Science and Technology, Shandong Academy of Agricultural Sciences, Jinan, 250100, People's Republic of China. nkzhhw@163.com.
  • Zhang X; School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing, 100081, People's Republic of China.
Mikrochim Acta ; 190(8): 318, 2023 Jul 25.
Article em En | MEDLINE | ID: mdl-37490216
ABSTRACT
A fluorometric and colorimetric dual-modal nanoprobe (denoted as Fe2+-Phen/SiNPs) has been developed for selective and sensitive determination of nitrite (NO2-). The mechanism is based on fluorescence quenching between silicon nanoparticles (SiNPs) and Fe(II)-phenanthroline complex (Fe2+-Phen) via inner filter effect and redox. With the addition of increasing NO2-, Fe2+ is oxidized to Fe3+, recovering the fluorescence of SiNPs. Meanwhile, the color of the system gradually changes from orange-red to colorless, which enables colorimetric measurement. The NO2- concentration shows a wide linear relationship with fluorescence intensity from 0.1 to 1.0 mM (R2 = 0.9955) with a detection limit of 2.4 µM in the fluorometric method (excitation wavelength 380 nm). By contrast, the linear range of the colorimetric method ranges from 0.01 to 0.35 mM (R2 = 0.9953) with a limit of detection of 6.8 µM (proposed selective absorbance 510 nm). The probe has been successfully applied to nitrite determination in water, salted vegetables, and hams demonstrating broad application prospects for the determination of nitrite in complicated matrices.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mikrochim Acta Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mikrochim Acta Ano de publicação: 2023 Tipo de documento: Article
...