Your browser doesn't support javascript.
loading
Variability and reproducibility of multi-echo T2 relaxometry: Insights from multi-site, multi-session and multi-subject MRI acquisitions.
Fischi-Gomez, Elda; Girard, Gabriel; Koch, Philipp J; Yu, Thomas; Pizzolato, Marco; Brügger, Julia; Piredda, Gian Franco; Hilbert, Tom; Cadic-Melchior, Andéol G; Beanato, Elena; Park, Chang-Hyun; Morishita, Takuya; Wessel, Maximilian J; Schiavi, Simona; Daducci, Alessandro; Kober, Tobias; Canales-Rodríguez, Erick J; Hummel, Friedhelm C; Thiran, Jean-Philippe.
Afiliação
  • Fischi-Gomez E; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Girard G; Translational Machine Learning Lab, Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland.
  • Koch PJ; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Yu T; CIBM Center for Biomedical Imaging, Lausanne, Switzerland.
  • Pizzolato M; Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland.
  • Brügger J; Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Piredda GF; Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland.
  • Hilbert T; Department of Neurology, University of Lübeck, Lübeck, Germany.
  • Cadic-Melchior AG; Center of Brain, Behavior and Metabolism (CBBM), University of Lübeck, Lübeck, Germany.
  • Beanato E; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Park CH; Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland.
  • Morishita T; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Wessel MJ; Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark.
  • Schiavi S; Defitech Chair for Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Daducci A; Defitech Chair of Clinical Neuroengineering, Neuro-X Institute (NIX) and Brain Mind Institute (BMI), École Polytechnique Fédérale de Lausanne (EPFL Valais), Clinique Romande de Réadaptation, Sion, Switzerland.
  • Kober T; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
  • Canales-Rodríguez EJ; Department of Radiology, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland.
  • Hummel FC; Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland.
  • Thiran JP; Signal Processing Laboratory 5 (LTS5), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
Front Radiol ; 2: 930666, 2022.
Article em En | MEDLINE | ID: mdl-37492668
ABSTRACT
Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T2 relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T2 relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space (T2IE) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T2 relaxometry dataset. To this end, we evaluated three different techniques for estimating the T2 spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that T2IE is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Radiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Front Radiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Suíça