Your browser doesn't support javascript.
loading
Realistic three-layer head phantom for optically pumped magnetometer-based magnetoencephalography.
Cao, Fuzhi; Gao, Zhenfeng; Qi, Shengjie; Chen, Kaihua; Xiang, Min; An, Nan; Ning, Xiaolin.
Afiliação
  • Cao F; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China.
  • Gao Z; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
  • Qi S; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
  • Chen K; Quanum Life Sciences, Hangzhou, 310051, China.
  • Xiang M; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejian
  • An N; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou, 310051, China; Hefei National Laboratory, He
  • Ning X; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Hangzhou Institute of National Extremely-weak Magnetic Field Infrastructure, Hangzhou 310028, China; Zhejian
Comput Biol Med ; 164: 107318, 2023 09.
Article em En | MEDLINE | ID: mdl-37595517
The advent of optically pumped magnetometer-based magnetoencephalography (OPM-MEG) has introduced new tools for neuroscience and clinical research. As it is still under development, the achievable performance of OPM-MEG remains to be tested, particularly in terms of source localization accuracy, which can be influenced by various factors, including software and hardware aspects. A feasible approach to comprehensively test the performance of the OPM-MEG system is to utilize a phantom that simulates the actual electrophysiological properties of the head while ensuring the precise locations of dipole sources. However, conventional water or dry phantoms can only simulate a single-sphere head model. In this work, a more realistic three-layer phantom was designed and fabricated. The proposed phantom included the scalp, skull, and cortex tissues of the head, as well as the simulated dipole sources. The scalp and cortex tissues were simulated using an electrolyte solution, while the dipole source was constructed from a coaxial cable. All main structures in the phantom were produced using 3D printing techniques, making the phantom easy to manufacture. The fabricated phantom was tested on a 36-channel OPM-MEG system, and the results showed that the dipole source inside the phantom could generate a magnetic field distribution on the scalp that was close to its theoretical values. The average source localization accuracy of 5.51 mm verified the effectiveness of the designed phantom and the performance of our OPM-MEG system. This work provides an effective test platform for OPM-MEG.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Córtex Cerebral Tipo de estudo: Prognostic_studies Idioma: En Revista: Comput Biol Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Magnetoencefalografia / Córtex Cerebral Tipo de estudo: Prognostic_studies Idioma: En Revista: Comput Biol Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos