Your browser doesn't support javascript.
loading
Development of liquid chromatography-triple quadrupole mass spectrometric method for the quantitative determination of a novel adjuvant, Imidazoquinoline gallamide in aluminum hydroxide gel-Imidazoquinoline gallamide and COVAXIN.
Nagendla, Narendra Kumar; Subrahanyam, Seetha Bala; Konda, Satyanand; Mudiam, Mohana Krishna Reddy.
Afiliação
  • Nagendla NK; Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Hyderabad, India.
  • Subrahanyam SB; Department of Analytical and Structural Chemistry, Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.
  • Konda S; Analytical and Structural Chemistry Department, CSIR-Indian Institute of Chemical Technology, Hyderabad, India.
  • Mudiam MKR; Department of Analytical and Structural Chemistry, Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.
J Sep Sci ; 46(20): e2300380, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37609812
Imidazoquinoline gallamide is a toll-like receptor 7/8 agonist, belongs to the imidazoquinoline class, has the potential to activate antigen-presenting cells, and enhances immune response, primarily Th1 response. The COVAXIN is a whole virion inactivated Coronavirus disease 2019 vaccine formulated with this novel adjuvant called, aluminum hydroxide gel Imidazoquinoline gallamide, wherein, Imidazoquinoline gallamide is chemisorbed onto aluminum hydroxide gel. Herein, an analytical method based on liquid chromatography-tandem mass spectrometry was developed to identify and quantify Imidazoquinoline gallamide in aluminum hydroxide gel Imidazoquinoline gallamide and COVAXIN. The multiple reaction monitoring transitions were optimized for Imidazoquinoline gallamide quantification are [M+H]+ ions with 512.24→343.19 m/z (quantifier ion) and 512.24→360.22 m/z (qualifier ion). The developed method was validated as per the international conference on harmonization quality2 revison1 guidelines. The method was linear in the range of 0.025-10 µg/mL with a coefficient of determination of 0.9985 and the limit of quantification is 0.025 µg/mL. The accuracy was in the range of 82-121 % and intra- and inter-day precision was less than 7.1% and 5.39%, respectively. The expanded uncertainty results are 9.2% for Imidazoquinoline gallamide in the sample. The validated method was successfully applied to evaluate Imidazoquinoline gallamide concentration in every batch of COVAXIN.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hidróxido de Alumínio / Vacinas contra COVID-19 Limite: Humans Idioma: En Revista: J Sep Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hidróxido de Alumínio / Vacinas contra COVID-19 Limite: Humans Idioma: En Revista: J Sep Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia País de publicação: Alemanha