Your browser doesn't support javascript.
loading
Accuracy of radiographic projections to guide cephalic screw position in pertrochanteric fracture: a cadaveric study.
Lazzarini, Francesco; Paoli, Tommaso; Cozzi Lepri, Andrea; Secci, Gregorio; Zanna, Luigi; Innocenti, Matteo; Matassi, Fabrizio; Carulli, Christian; Civinini, Roberto.
Afiliação
  • Lazzarini F; Orthopaedic Clinic, University of Florence, Careggi University Hospital, Largo Palagi 1, 50139, Florence, Italy.
  • Paoli T; Department of Orthopedic Surgery, Santa Maria Annunziata Hospital,, Via Antella 58, 50012, Bagno a Ripoli, Italy.
  • Cozzi Lepri A; Orthopaedic Clinic, University of Florence, Careggi University Hospital, Largo Palagi 1, 50139, Florence, Italy.
  • Secci G; Department of Orthopedic Surgery, Santa Maria Annunziata Hospital,, Via Antella 58, 50012, Bagno a Ripoli, Italy.
  • Zanna L; Orthopaedic Clinic, University of Florence, Careggi University Hospital, Largo Palagi 1, 50139, Florence, Italy.
  • Innocenti M; Orthopaedic Clinic, University of Florence, Careggi University Hospital, Largo Palagi 1, 50139, Florence, Italy. gregorio.secci@unifi.it.
  • Matassi F; Department of Orthopedic Surgery, Santa Maria Annunziata Hospital,, Via Antella 58, 50012, Bagno a Ripoli, Italy. gregorio.secci@unifi.it.
  • Carulli C; Orthopaedic Clinic, University of Florence, Careggi University Hospital, Largo Palagi 1, 50139, Florence, Italy.
  • Civinini R; Department of Orthopedic Surgery, Santa Maria Annunziata Hospital,, Via Antella 58, 50012, Bagno a Ripoli, Italy.
Eur J Orthop Surg Traumatol ; 34(1): 479-487, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37624410
ABSTRACT

PURPOSE:

The aim of this study was to evaluate the relationship between the Löwenstein Lateral view and the True Lateral view for the positioning of the cephalic hip screw, through a cadaveric study. MATERIALS AND

METHODS:

We placed two Kirschner wires in eight femur specimens using an Antero-Posterior view, Löwenstein Lateral view and True Lateral view. The distances between the Kirschner wires and the anterior, posterior, superior and inferior cortex were measured in all projections. The head of the femur was then sectioned, and the same macroscopic distances were measured. Finally, we could calculate the accuracy of the two radiographic lateral projections.

RESULTS:

When the Kirschner wire was placed in the center of the head using the Antero-Posterior and the True Lateral view, the accuracy of Antero-Posterior view was 0.9705 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1479 and 1.1584, respectively. When the Kirschner wire was placed superior on the Antero-Posterior and centrally on the True Lateral view, the accuracy of Antero-Posterior view was 0.9930 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1159 and 0.7224, respectively.

CONCLUSION:

When the Kirschner wire was positioned proximal in Antero-Posterior view and central in True Lateral view, only the True Lateral view showed high accuracy.