Your browser doesn't support javascript.
loading
Clinical Outcomes and Prognostic Factors in Complex, High-Risk Indicated Procedure (CHIP) and High-Bleeding-Risk (HBR) Patients Undergoing Percutaneous Coronary Intervention with Sirolimus-Eluting Stent Implantation: 4-Year Results.
Tyczynski, Maciej; Kern, Adam; Buller, Patryk; Wanha, Wojciech; Gil, Robert J; Bil, Jacek.
Afiliação
  • Tyczynski M; Department of Invasive Cardiology, Center of Postgraduate Medical Education, 02-508 Warsaw, Poland.
  • Kern A; Department of Cardiology and Internal Medicine, School of Medicine, Collegium Medicum, University of Warmia and Mazury, 10-082 Olsztyn, Poland.
  • Buller P; Department of Cardiology, Provincial Integrated Hospital, 09-400 Plock, Poland.
  • Wanha W; Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, 40-635 Katowice, Poland.
  • Gil RJ; Department of Cardiology, State Medical Institute of the Ministry of Interior and Administration, 02-508 Warsaw, Poland.
  • Bil J; Department of Invasive Cardiology, Center of Postgraduate Medical Education, 02-508 Warsaw, Poland.
J Clin Med ; 12(16)2023 Aug 15.
Article em En | MEDLINE | ID: mdl-37629356
ABSTRACT
We aimed to characterize the performance and safety of percutaneous coronary intervention (PCI) in complex, high-risk indicated procedure (CHIP) and high-bleeding-risk (HBR) patients at a 4-year follow up. We included all consecutive patients who underwent PCI with the sirolimus-eluting coronary stent Alex Plus (Balton, Poland) between July 2015 and March 2016. We analyzed various baseline demographic and clinical characteristics, laboratory data, and clinical outcomes. We enrolled 232 patients in whom 282 stents were implanted, including 81 patients meeting the CHIP criteria and 76 patients meeting the HBR criteria. In the whole population, the mean age was 68 ± 11 years, and 23.7% were females. Most procedures were performed from radial access (83.2%) using a 6F guiding catheter (95.7%). The lesions were mostly predilated (61.6%), and postdilatation was performed in 37.9%. The device success was 99.6% (in one case, a second stent was required due to heavy calcifications). Additional stents were deployed in 39% of cases due to edge dissection (6.9%), side branch stenting (5.2%), or diffuse disease (26.9%). Myocardial infarction (MI) type 4a was revealed in 2.2% of cases. At 4 years, the MACE rates for the whole population and for CHIP and HBR patients were 23.3%, 29.6%, and 27.6%, respectively. CHIP patients had a higher risk of MACEs (29.6% vs. 19.9%, HR 1.69, p = 0.032) and cardiac death (11.1% vs. 4.6%, HR 2.50, p = 0.048). There were no differences for MI (7.4% vs. 6.6%, p = 0.826) and TLR (18.5% vs. 12.6%, p = 0.150). HBR patients were also characterized by a higher risk of MACEs (27.6% vs. 21.2%, HR 1.84, p = 0.049) and cardiac death (17.1% vs. 1.9%, HR 9.61, p < 0.001). There were no differences for MI (7.9% vs. 6.4%, p = 0.669) and TLR (11.8% vs. 16.0%, p = 0.991). PCI in CHIP and HBR patients is feasible with a low rate of periprocedural complications. Nevertheless, CHIP and HBR patients are at a high risk of future adverse events and require strict surveillance to improve outcomes.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Clin Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: J Clin Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Polônia
...