Your browser doesn't support javascript.
loading
Quality of life in the course of a one-year use of an advanced hybrid closed-loop system in adults with type 1 diabetes previously naïve to advanced diabetes technology.
Cyranka, Katarzyna; Matejko, Bartlomiej; Juza, Anna; Kiec-Wilk, Beata; Cohen, Ohad; Malecki, Maciej T; Klupa, Tomasz.
Afiliação
  • Cyranka K; Department of Metabolic Diseases, Jagiellonian University Medical College, Krakow, Poland.
  • Matejko B; University Hospital in Krakow, Krakow, Poland.
  • Juza A; Department of Psychiatry, Jagiellonian University Medical College, Krakow, Poland.
  • Kiec-Wilk B; Department of Metabolic Diseases, Jagiellonian University Medical College, Krakow, Poland.
  • Cohen O; University Hospital in Krakow, Krakow, Poland.
  • Malecki MT; Clinical Provincial Hospital of Frederic Chopin No. 1 in Rzeszów, Rzeszów, Poland.
  • Klupa T; College of Medical Sciences, University of Rzeszów, Rzeszów, Poland.
Front Endocrinol (Lausanne) ; 14: 1210756, 2023.
Article em En | MEDLINE | ID: mdl-37654566
Aim: To evaluate the effect of a one-year use of an advanced hybrid closed-loop (AHCL) system on the quality of life, level of anxiety, and level of self-efficacy in adults with type 1 diabetes (T1D) previously treated with multiple daily injections (MDI) and naïve to advanced diabetes technology. Methods: A total of 18 participants of a previously published 3-month randomized trial (10 men, 8 women; age 40.9 ± 7.6 years) who were switched directly from MDI/BMG to AHCL completed 12 months of MiniMed 780G™system use (a 3-month randomized trial followed by a 9-month follow-up phase). At month 6 of the study, patients were switched from the sensor GS3 (Continuous Glucose Monitoring) system, powered by Guardian™ Sensor 3) to GS4. Quality of life was assessed using the Polish validated version of the 'QoL-Q Diabetes' questionnaire. The level of anxiety was evaluated with the use of the State-Trait Anxiety Inventory (STAI). Self-efficacy was assessed with the General Self-Efficacy Scale (GSES). Results were obtained at baseline and at the end of the study. Results: Significant increase in QoL was reported in the global score (p=0.02, Cohen d=0.61) and in as many as 11 out of 23 analyzed areas of life: being physically active (p=0.02, Cohen d = 0.71); feeling well (p<.01, Cohen d = 0.73); feeling in control of my body (p<.01, Cohen d = 0.72); looking good (p<.01, Cohen d = 1.07); working (p<.01, Cohen d = 1.12); sleeping (p=0.01, Cohen d = 0.66); eating as I would like (p<.01, Cohen d = 0.79); looking after or being useful to others (p= 0.02, Cohen d = 0.65); being active with pets/animals (p<.01, Cohen d = 0.95); being spontaneous (p=0.02, Cohen d = 0.67); and doing "normal" things (p=0.02, Cohen d = 0.67). Both state (p=0.04, Cohen d = 0.56) and trait (p=0.02, Cohen d = 0.60) anxiety decreased while the general self-efficacy increased (p=0.03, Cohen d = 0.76). No participant stopped the use of the pump. Conclusion: Adult patients with T1D previously treated with MDI and naïve to modern technologies experienced significant improvement in their psychological well-being after transitioning to the AHCL system after 12 months of treatment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Aspecto: Patient_preference Idioma: En Revista: Front Endocrinol (Lausanne) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Polônia País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials Aspecto: Patient_preference Idioma: En Revista: Front Endocrinol (Lausanne) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Polônia País de publicação: Suíça