Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study.
Stein, Thomas; Taron, Jana; Verloh, Niklas; Doppler, Michael; Rau, Alexander; Hagar, Muhammad Taha; Faby, Sebastian; Baltas, Dimos; Westermann, Dirk; Ayx, Isabelle; Schönberg, Stefan O; Nikolaou, Konstantin; Schlett, Christopher L; Bamberg, Fabian; Weiss, Jakob.
Afiliação
  • Stein T; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany. thomas.stein@uniklinik-freiburg.de.
  • Taron J; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Verloh N; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Doppler M; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Rau A; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Hagar MT; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Faby S; Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany.
  • Baltas D; Division of Medical Physics, Department of Radiation Oncology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Westermann D; German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany.
  • Ayx I; Department of Cardiology and Angiology, Interdisciplinary Vascular Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Schönberg SO; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany.
  • Nikolaou K; Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany.
  • Schlett CL; Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany.
  • Bamberg F; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Weiss J; Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Sci Rep ; 13(1): 14806, 2023 09 08.
Article em En | MEDLINE | ID: mdl-37684412
ABSTRACT
Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0-8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3-4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Prótese Vascular / Tomografia Computadorizada por Raios X Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Prótese Vascular / Tomografia Computadorizada por Raios X Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha