Your browser doesn't support javascript.
loading
A flexible and wearable three-electrode electrochemical sensing system consisting of a two-in-one enzyme-mimic working electrode.
Wang, Yanan; Liu, Yali; Wang, Xiao; Cao, Xiyue; Xia, Jianfei; Wang, Zonghua.
Afiliação
  • Wang Y; College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Center of Qingdao University, Qingdao University, Qingdao, 266071, PR China.
  • Liu Y; Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, 266071, PR China.
  • Wang X; College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Center of Qingdao University, Qingdao University, Qingdao, 266071, PR China.
  • Cao X; College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Center of Qingdao University, Qingdao University, Qingdao, 266071, PR China. Electronic address: caoxiyue@qdu.edu.cn.
  • Xia J; College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Center of Qingdao University, Qingdao University, Qingdao, 266071, PR China. Electronic address: xiajianfei@126.com.
  • Wang Z; College of Chemistry and Chemical Engineering, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Instrumental Analysis Center of Qingdao University, Qingdao University, Qingdao, 266071, PR China.
Anal Chim Acta ; 1278: 341688, 2023 Oct 16.
Article em En | MEDLINE | ID: mdl-37709441
ABSTRACT
In this work, a wearable and flexible three-electrode electrochemical sensing system (TESS) by using a two-in-one enzyme-mimic working electrode (TIOWE) is reported. The integrated three-electrode, including working electrodes, reference electrodes, and counter electrodes are formed by transfer printing of Ni2P-based composite electrode ink (Ni2P/G ink), Ag/AgCl ink, and carbon ink onto PDMS substrate, respectively. The Ni2P/G ink-based working electrodes have both good conductivity and enzyme-mimic catalytic activity towards glucose. Under optimized conditions, the TIOWE-TESS has a low detection limit of 0.37 µM and wide linear ranges of 0.001 mM-0.1 mM and 0.1 mM-1.4 mM. Furthermore, the TIOWE-TESS has good applicability in serum samples and reveals remarkable electrochemical performance at fluctuant working temperatures. The proposed TIOWE-TESS can be integrated on a waterproof bandage to fabricate a skin-friendly patch device for sweet glucose monitoring, which highlights its potential applications in flexible and wearable commercial devices for health-monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Automonitorização da Glicemia Idioma: En Revista: Anal Chim Acta Ano de publicação: 2023 Tipo de documento: Article