Your browser doesn't support javascript.
loading
Interlaminar endoscopic uniportal approach for implantation of a paddle lead larger than 10 mm for spinal cord stimulation: illustrative case.
Lages, Gustavo V; Barbosa, Ramon G; Souto, Hugo S; Santiago, Natally M; Júnior, José Oswaldo O; Serra, Marcus V F B V F; Batista, Leandro F; Silva, Camille L; Toledo, Maria Fernanda A V.
Afiliação
  • Lages GV; 1Department of Neurosurgery, MEDULAR, Montes Claros, Minas Gerais, Brazil.
  • Barbosa RG; 1Department of Neurosurgery, MEDULAR, Montes Claros, Minas Gerais, Brazil.
  • Souto HS; 2Department of Anesthesiology, Hospital Dilson Godinho, Montes Claros, Minas Gerais, Brazil.
  • Santiago NM; 3Department of Neurosurgery, Hospital Beneficência Portuguesa, São Paulo, São Paulo, Brazil.
  • Júnior JOO; 4Department of Neurosurgery, Pain ans Stereotaxis Center at the AC Camargo Cancer Center, São Paulo, São Paulo, Brazil.
  • Serra MVFBVF; 5Department of Neurosurgery, Santista Institute of Neurosurgery and Spine, Santos, São Paulo, Brazil.
  • Batista LF; 6Neurosurgery residency, Santa Casa, Montes Claros, Minas Gerais, Brazil; and.
  • Silva CL; 7Medical school, UNIFIPMOC Afya, Montes Claros, Minas Gerais, Brazil.
  • Toledo MFAV; 7Medical school, UNIFIPMOC Afya, Montes Claros, Minas Gerais, Brazil.
J Neurosurg Case Lessons ; 6(10)2023 Sep 04.
Article em En | MEDLINE | ID: mdl-37728238
ABSTRACT

BACKGROUND:

The authors aim to describe a new technique for implantation of a spinal cord stimulation paddle lead sized over 10 mm through an endoscopic uniportal approach. A new endoscopic cannula was developed for the passage of a paddle lead width between 10 and 13 mm. The distal portion of the cannula was designed with a larger opening, providing better visibility of the anterior portion of the adjacent structures, thus allowing a panoramic view of the electrode passage. An electrode was implanted in an 11-mm paddle. OBSERVATIONS After searching PubMed, Cochrane, and Lilacs databases, the authors found no mention of the implantation of a paddle electrode with a width greater than 10 mm. The implantation of a paddle electrode less than 10 mm wide is possible via endoscopic access using 10-mm working channels. However, for electrodes with a width greater than 10 mm, access via endoscopy is impossible, since the working channel is only 10 mm. LESSONS The authors concluded that it is possible to pass electrodes safely and effectively with a paddle width between 10 and 13 mm using spinal endoscopy via uniportal interlaminar access. However, it is necessary to expand studies to elucidate this technique of endoscopic implantation of electrodes for neurostimulation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurosurg Case Lessons Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Neurosurg Case Lessons Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil