Your browser doesn't support javascript.
loading
Microfluidic design for in-vitro liver zonation-a numerical analysis using COMSOL Multiphysics.
Mahdavi, Reza; Hashemi-Najafabadi, Sameereh; Ghiass, Mohammad Adel; Adiels, Caroline Beck.
Afiliação
  • Mahdavi R; Biotechnology Department, Faculty of Chemical Engineering, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran.
  • Hashemi-Najafabadi S; Biomedical Engineering Department, Faculty of Chemical Engineering, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran. s.hashemi@modares.ac.ir.
  • Ghiass MA; Tissue Engineering Department, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, P.O. Box 14115-114, Iran.
  • Adiels CB; Department of Physics, University of Gothenburg, 41296, Gothenburg, Sweden. caroline.adiels@physics.gu.se.
Med Biol Eng Comput ; 62(1): 121-133, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37733153
The liver is one of the most important organs, with a complex physiology. Current in-vitro approaches are not accurate for disease modeling and drug toxicity research. One of those features is liver zonation, where cells display different physiological states due to different levels of oxygen and nutrient supplements. Organ-on-a-chip technology employs microfluidic platforms that enable a controlled environment for in-vitro cell culture. In this study, we propose a microfluidic design embedding a gas channel (of ambient air), creating an oxygen gradient. We numerically simulate different flow rates and cell densities with the COMSOL Multiphysics package considering cell-specific consumption rates of oxygen and glucose. We establish the cell density and flow rate for optimum oxygen and glucose distribution in the cell culture chamber. Furthermore, we show that a physiologically relevant concentration of oxygen and glucose in the chip is reached after 24 h and 30 min, respectively. The proposed microfluidic design and optimal parameters we identify in this paper provide a tool for in-vitro liver zonation studies. However, the microfluidic design is not exclusively for liver cell experiments but is foreseen to be applicable in cell studies where different gas concentration gradients are critical, e.g., studying hypoxia or toxic gas impact.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Fígado Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microfluídica / Fígado Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã País de publicação: Estados Unidos