Your browser doesn't support javascript.
loading
Comparing MS imaging of lipids by WALDI and MALDI: two technologies for evaluating a common ground truth in MS imaging.
Ledoux, Léa; Zirem, Yanis; Renaud, Florence; Duponchel, Ludovic; Salzet, Michel; Ogrinc, Nina; Fournier, Isabelle.
Afiliação
  • Ledoux L; Univ. Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France. isabelle.fournier@univ-lille.fr.
  • Zirem Y; Univ. Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France. isabelle.fournier@univ-lille.fr.
  • Renaud F; Unité mixte SIRIC CURAMUS et 938, Inserm. Université Paris Sorbonne, France.
  • Duponchel L; Univ. Lille, CNRS, UMR 8516 - LASIRE, F-59000 Lille, France.
  • Salzet M; Univ. Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France. isabelle.fournier@univ-lille.fr.
  • Ogrinc N; Institut Universitaire de France (IUF), Paris, France.
  • Fournier I; Univ. Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France. isabelle.fournier@univ-lille.fr.
Analyst ; 148(20): 4982-4986, 2023 Oct 05.
Article em En | MEDLINE | ID: mdl-37740342
In this study, we conducted a direct comparison of water-assisted laser desorption ionization (WALDI) and matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging, with MALDI serving as the benchmark for label-free molecular tissue analysis in biomedical research. Specifically, we investigated the lipidomic profiles of several biological samples and calculated the similarity of detected peaks and Pearson's correlation of spectral profile intensities between the two techniques. We show that, overall, MALDI MS and WALDI MS present very close lipidomic analyses and that the highest similarity is obtained for the norharmane MALDI matrix. Indeed, for norharmane in negative ion mode, the lipidomic spectra revealed 100% similarity of detected peaks and over 0.90 intensity correlation between both technologies for five samples. The MALDI-MSI positive ion lipid spectra displayed more than 83% similarity of detected peaks compared to those of WALDI-MSI. However, we observed a lower percentage (77%) of detected peaks when comparing WALDI-MSI with MALDI-MSI due to the rich WALDI-MSI lipid spectra. Despite this difference, the global lipidomic spectra showed high consistency between the two technologies, indicating that they are governed by similar processes. Thanks to this similarity, we can increase datasets by including data from both modalities to either co-train classification models or obtain cross-interrogation.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Analyst Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França País de publicação: Reino Unido