Your browser doesn't support javascript.
loading
Prognostic accuracy of initial and 24-h maximum SOFA scores of septic shock patients in the emergency department.
Kim, Tae Han; Jeong, Daun; Park, Jong Eun; Hwang, Sung Yeon; Suh, Gil Joon; Choi, Sung-Hyuk; Chung, Sung Phil; Kim, Won Young; Lee, Gun Tak; Shin, Tae Gun.
Afiliação
  • Kim TH; Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Jeong D; Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Park JE; Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Hwang SY; Department of Emergency Medicine, College of Medicine, Kangwon National University, Chuncheon, Gangwon-do, Republic of Korea.
  • Suh GJ; Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Choi SH; Department of Emergency Medicine, College of Medicine, Seoul National University, Seoul, Republic of Korea.
  • Chung SP; Department of Emergency Medicine, College of Medicine, Korea University, Seoul, Republic of Korea.
  • Kim WY; Department of Emergency Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Lee GT; Department of Emergency Medicine, College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
  • Shin TG; Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Heliyon ; 9(9): e19480, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37809700
ABSTRACT

Background:

We compared the prognostic accuracy of in-hospital mortality of the initial Sequential Organ Failure Assessment (SOFAini) score at the time of sepsis recognition and resuscitation and the maximum SOFA score (SOFAmax) using the worst variables in the 24 h after the initial score measurement in emergency department (ED) patients with septic shock.

Methods:

This was a retrospective observational study using a multicenter prospective registry of septic shock patients in the ED between October 2015 and December 2019. The primary outcome was in-hospital mortality. The prognostic accuracies of SOFAini and SOFAmax were evaluated using the area under the receiver operating characteristic (AUC) curve.

Results:

A total of 4860 patients was included, and the in-hospital mortality was 22.1%. In 59.7% of patients, SOFAmax increased compared with SOFAini, and the mean change of total SOFA score was 2.0 (standard deviation, 2.3). There was a significant difference in in-hospital mortality according to total SOFA score and the SOFA component scores, except cardiovascular SOFA score. The AUC of SOFAmax (0.71; 95% confidence interval [CI], 0.69-0.72) was significantly higher than that of SOFAini (AUC, 0.67; 95% CI, 0.66-0.69) in predicting in-hospital mortality. The AUCs of all scores of the six components were higher for the maximum values.

Conclusion:

The prognostic accuracy of the initial SOFA score at the time of sepsis recognition was lower than the 24-h maximal SOFA score in ED patients with septic shock. Follow-up assessments of organ failure may improve discrimination of the SOFA score for predicting mortality.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Idioma: En Revista: Heliyon Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Idioma: En Revista: Heliyon Ano de publicação: 2023 Tipo de documento: Article