A two-stage SCUC model for distribution networks considering uncertainty and demand response.
Heliyon
; 9(10): e20189, 2023 Oct.
Article
em En
| MEDLINE
| ID: mdl-37810800
ABSTRACT
Demand response (DR) is one of the most effective and economical methods for power operators to improve network reliability in face of uncertainty and emergencies. In this paper, considering the uncertainty of wind power output and the failure of power system components, a two-stage security-constrained unit commitment (SCUC) model is established by optimizing the real-time pricing mechanism to indirectly adjust the DR. Firstly, the uncertainty of wind power output is modeled based on self-organizing map (SOM), and the component failure of the power system is modeled based on Monte Carlo. Then, a pricing scheme is proposed to stimulate users' electricity consumption behavior. Finally, the marine predator algorithm is used to solve the problem. Simulation results on IEEE-RTS system show that the proposed method can reduce the total operating cost by 10%, effectively stimulate the electricity consumption behavior of users, to improve the peak load shifting and valley filling capacity of the power system.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Revista:
Heliyon
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
China