Your browser doesn't support javascript.
loading
A green method for the determination of illicit drugs in wastewater and surface waters-based on a semi-automated liquid-liquid microextraction device.
Nascimento, Madson Moreira; Nascimento, Melise Lemos; Pereira Dos Anjos, Jeancarlo; Cunha, Ricardo Leal; da Rocha, Gisele Olimpio; Ferreira Dos Santos, Ivanice; Pereira, Pedro Afonso de Paula; de Andrade, Jailson Bittencourt.
Afiliação
  • Nascimento MM; Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil.
  • Nascimento ML; Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil.
  • Pereira Dos Anjos J; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Centro Universitário SENAI CIMATEC, Av. Orlando Gomes, 1845 - Piatã, Salvador, BA 41650-010, Brazil.
  • Cunha RL; Laboratório de Toxicologia Forense, Instituto de Análises e Pesquisas Forenses - IAPF, Polícia Científica, São Cristóvão, SE 49100-000, Brazil; Faculdade de Ciências Farmacêuticas, Universidade Estadual de Campinas, Campinas, SP 13083-859, Brazil.
  • da Rocha GO; Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto de Química, Universidade Federal da Bahia, Campus de Ondina, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Unive
  • Ferreira Dos Santos I; Universidade Estadual de Feira de Santana, Av. Transnordestina, s/n - Feira de Santana, Novo Horizonte - BA 44036-900, BA, Brazil.
  • Pereira PAP; Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto de Química, Universidade Federal da Bahia, Campus de Ondina, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Unive
  • de Andrade JB; Centro Interdisciplinar de Energia e Ambiente - CIEnAm, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Instituto Nacional de Ciência e Tecnologia em Energia e Ambiente - INCT, Universidade Federal da Bahia, Salvador, BA 40170-115, Brazil; Centro Universitário SENAI CIMATEC, Av. Orlan
J Chromatogr A ; 1710: 464230, 2023 Nov 08.
Article em En | MEDLINE | ID: mdl-37826922
ABSTRACT
Liquid-phase microextraction (LPME) is a simple, low-cost, and eco-friendly technique that enables the detection of trace concentrations of organic contaminants in water samples. In this work, a novel customized microextraction device was developed for the LPME extraction and preconcentration of nine illicit drugs in surface water and influent and effluent wastewater samples, followed by analysis by GC-MS without derivatization. The customized device was semi-automated by coupling it with a peristaltic pump to perform the collection of the upper layer of the organic phase. The extraction parameters affecting the LPME efficiency were optimized. The optimized conditions were 100 µL of a toluene/DCM/EtAc mixture as extractor solvent; 30min of extraction time under vortex agitation (500rpm) and a solution pH of 11.6. The limits of detection and quantification ranged from 10.5ng L-1 (ethylone) to 22.0ng L-1 (methylone), and from 34.9ng L-1 to 73.3ng L-1 for these same compounds, respectively. The enrichment factors ranged from 39.7 (MDMA) to 117 (cocaethylene) and the relative recoveries ranged from 80.4% (N-ethylpentylone) to 120% (cocaine and cocaine-d3). The method was applied to real surface water, effluent, and influent wastewater samples collected in Salvador City, Bahia, Brazil. Cocaine was the main drug detected and quantified in wastewater samples, and its concentration ranged from 312ng L-1 to 1,847ng L-1. Finally, the AGREE metrics were applied to verify the greenness of the proposed method, and an overall score of 0.56 was achieved, which was considered environmentally friendly.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Drogas Ilícitas / Cocaína / Microextração em Fase Líquida Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Drogas Ilícitas / Cocaína / Microextração em Fase Líquida Idioma: En Revista: J Chromatogr A Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Brasil