Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods.
Takács, Anna; Hardi, Eszter; Cavalcante, Bianca Golzio Navarro; Szabó, Bence; Kispélyi, Barbara; Joób-Fancsaly, Árpád; Mikulás, Krisztina; Varga, Gábor; Hegyi, Péter; Kivovics, Márton.
Afiliação
  • Takács A; Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary.
  • Hardi E; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary.
  • Cavalcante BGN; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary.
  • Szabó B; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary.
  • Kispélyi B; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary.
  • Joób-Fancsaly Á; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary.
  • Mikulás K; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary.
  • Varga G; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary.
  • Hegyi P; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary; Institute for Translational Medicine, Szentágothai Research Centre, Medical School, University of Pécs, Szigeti út 12. 7624 Pécs, Hungary; Division of Pancreatic Diseases, Heart and Vascular Center, Semmel
  • Kivovics M; Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Ülloi út 26. 1085 Budapest, Hungary. Electronic address: kivovics.marton@dent.semmelweis-univ.hu.
J Dent ; 139: 104748, 2023 12.
Article em En | MEDLINE | ID: mdl-37863173
ABSTRACT

OBJECTIVES:

This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. DATA In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. SOURCES A systematic search was performed on April 18, 2023, using the following three databases MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search.

RESULTS:

A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors.

CONCLUSIONS:

Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. CLINICAL

SIGNIFICANCE:

To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Cirurgia Assistida por Computador Tipo de estudo: Systematic_reviews Idioma: En Revista: J Dent Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Hungria

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Cirurgia Assistida por Computador Tipo de estudo: Systematic_reviews Idioma: En Revista: J Dent Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Hungria