XRF online analyzer for measurements of P2O5 content in phosphate slurry.
Ben Amar, Ismail; Thomas, Andrew; Bachmann, Claus; Hafnaoui, Anass; Griguer, Hafid; Miled, Amine; Messaddeq, Younès.
Afiliação
  • Ben Amar I; Department of Electrical and Computer Engineering, Université Laval, Quebec City, QC, Canada. ismail.ben-amar.1@ulaval.ca.
  • Thomas A; Digital Innovation Center of Excellence DICE, Mohammed VI Polytechnic University UM6P, Ben Guerir, Morocco. ismail.ben-amar.1@ulaval.ca.
  • Bachmann C; Center for Optics, Photonics, and Lasers, Université Laval, Quebec City, QC, Canada. ismail.ben-amar.1@ulaval.ca.
  • Hafnaoui A; J&C Bachmann GmbH, Pfinztal, Germany.
  • Griguer H; J&C Bachmann GmbH, Pfinztal, Germany.
  • Miled A; OCP Group S.A, Jorf Lasfar, El Jadida, Morocco.
  • Messaddeq Y; Digital Innovation Center of Excellence DICE, Mohammed VI Polytechnic University UM6P, Ben Guerir, Morocco.
Sci Rep ; 13(1): 17925, 2023 Oct 20.
Article em En | MEDLINE | ID: mdl-37864005
Online X-ray Fluorescence (XRF) setup was constructed and optimized for analysing the P2O5 content in phosphate slurry (PS). Serval samples were analysed using two configurations of the setup, one with low and vertical flow and another with high and horizontal flow. The mean absolute error achieved through the first configuration was 0.87% and 0.38% using the second configuration. Reference samples were analyzed using the two configurations to construct the calibration curves. The curves cover a concentration range of P2O5 from 13.50 to 18.50% when considering the horizontal flow configuration, and a range of 14.00-15.60% when considering the vertical flow setup. An experimental study was conducted in order to optimize the measurement parameters for the online measurement of P2O5 in the phosphate slurry using the horizontal flow setup. A good signal-to-noise ratio (SNR) of [Formula: see text] was attained using an excitation energy of 20 kV or 25 kV, an excitation current of 600 µA, a distance of 18 mm between the sample and the detector, a measurement time of 60 s per spectrum and the use of an Aluminum filter between the X-ray tube and the measurement window. Online X-ray fluorescence analysis of P entails some challenges due to the low characteristic energy of P, the phosphate slurry matrix and the online analysis mode. However, the outcomes of this study indicate that XRF is a promising technology to meet the requirement for digitalization of chemical analysis of phosphate products.