Comparative Study of 2D-Cine and 3D-wh Volumetry: Revealing Systemic Error of 2D-Cine Volumetry.
Alkassar, Muhnnad; Engelhardt, Sophia; Abu-Tair, Tariq; Ojeda, Efren; Treffer, Philipp C; Weyand, Michael; Rompel, Oliver.
Afiliação
  • Alkassar M; Department of Cardiac Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
  • Engelhardt S; Department of Pediatrics, Paracelsus Medical School, General Hospital of Nuremberg, 90419 Nuremberg, Germany.
  • Abu-Tair T; Department of Cardiac Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
  • Ojeda E; Department of Congenital Heart Disease, Centre for Diseases in Childhood and Adolescence, University Medicine Mainz, 55131 Mainz, Germany.
  • Treffer PC; Siemens Healtineers, 91052 Erlangen, Germany.
  • Weyand M; Siemens Healtineers, 91052 Erlangen, Germany.
  • Rompel O; Department of Cardiac Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91054 Erlangen, Germany.
Diagnostics (Basel) ; 13(20)2023 Oct 10.
Article em En | MEDLINE | ID: mdl-37891983
ABSTRACT
This study investigates the crucial factors influencing the end-systolic and end-diastolic volumes in MRI volumetry and their direct effects on the derived functional parameters. Through the simultaneous acquisition of 2D-cine and 3D whole-heart slices in end-diastole and end-systole, we present a novel direct comparison of the volumetric measurements from both methods. A prospective study was conducted with 18 healthy participants. Both 2D-cine and 3D whole-heart sequences were obtained. Despite the differences in the creation of 3D volumes and trigger points, the impact on the LV volume was minimal (134.9 mL ± 16.9 mL vs. 136.6 mL ± 16.6 mL, p < 0.01 for end-diastole; 50.6 mL ± 11.0 mL vs. 51.6 mL ± 11.2 mL, p = 0.03 for end-systole). In our healthy patient cohort, a systematic underestimation of the end-systolic volume resulted in a significant overestimation of the SV (5.6 mL ± 2.6 mL, p < 0.01). The functional calculations from the 3D whole-heart method proved to be highly accurate and correlated well with function measurements from the phase-contrast sequences. Our study is the first to demonstrate the superiority of 3D whole-heart volumetry over 2D-cine volumetry and sheds light on the systematic error inherent in 2D-cine measurements.