Your browser doesn't support javascript.
loading
Vertical versus angled immediately loaded implants for assisting maxillary overdentures with locator attachments: A preliminary results of one-year randomized clinical trial.
Aboelez, Marwa Ahmed; Ibrahim, Christine Raouf Micheal; Helmy, Mohamad Hossam El-Din; Elsyad, Moustafa Abdou.
Afiliação
  • Aboelez MA; Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
  • Ibrahim CRM; Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
  • Helmy MHE; Faculty of Dentistry, Assiut University, Assiut, Egypt.
  • Elsyad MA; Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Clin Implant Dent Relat Res ; 26(1): 103-112, 2024 Feb.
Article em En | MEDLINE | ID: mdl-37926953
OBJECTIVES: This study aimed to evaluate the clinical outcomes and patient satisfaction of 4-implant-assisted maxillary overdentures using two different designs. MATERIALS AND METHODS: Thirty edentulous participants received four implants in the maxillary ridge. The patients were randomly divided into two equal groups: (1) the control (CG, Vertical) group (n = 15); participants received four vertical implants with straight locator attachments to retain maxillary overdentures, and (2) the study (SG, Angled) group (n = 15); participants received four angled implants with angled locator attachments to retain maxillary overdentures. Peri-implant tissue health [Plaque (PL) and gingival (GI) indices, pocket depth (PD), implant stability (ISQ) and crestal bone loss (CBL)] were evaluated after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion. Patient satisfaction was evaluated using a visual analog scale (VAS) after 12 months. RESULTS: The survival rates were 96.7% and 95% for the control and study groups respectively. PL, GI, and PD increased significantly in both groups with the passage of time. No significant difference in PL, GI, PD, and ISQ was noted between groups at all observation times. CG showed higher CBL than SG at T12. For the VAS results, there was no significant difference between groups. SG recorded significantly higher satisfaction regarding comfort with maxillary and mandibular dentures, retention of mandibular dentures, oral hygiene, the ability to chew hard food, and occlusion than CG. CONCLUSION: Within the limitations of this study, angled implants with angled locator attachments may be recommended to retain maxillary overdentures opposing intact dentition or fixed restoration as it was associated with improvements of several parameters of peri-implant tissue health and patient satisfaction compared to vertical implants with straight locator attachments.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Arcada Edêntula / Placa Dentária Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Egito País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Arcada Edêntula / Placa Dentária Limite: Humans Idioma: En Revista: Clin Implant Dent Relat Res Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Egito País de publicação: Estados Unidos