Your browser doesn't support javascript.
loading
The effect of N95 designs on respirator fit and its associations with gender and facial dimensions.
Khairul Hasni, Nurul Amalina; Ismail, Rohaida; Muhamad Robat, Rosnawati; Mohamad, Nadia; Suib, Fatin Amirah; Pahrol, Muhammad Alfatih; Mahmud, Haalah; Osman, Baderin; Lim, Yin Cheng; Seman, Zamtira; Shaharudin, Rafiza.
Afiliação
  • Khairul Hasni NA; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Ismail R; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Muhamad Robat R; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Mohamad N; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Suib FA; Infectious Disease Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Pahrol MA; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
  • Mahmud H; National Institute of Occupational Safety and Health, Ministry of Human Resources, Malaysia.
  • Osman B; National Institute of Occupational Safety and Health, Ministry of Human Resources, Malaysia.
  • Lim YC; Department of Social and Preventive Medicine, Faculty of Medicine, University Malaya, Kuala Lumpur, Malaysia.
  • Seman Z; Sector for Biostatistics & Data Repository, National Institutes of Health, Ministry of Health, Malaysia.
  • Shaharudin R; Environmental Health Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health, Malaysia.
PLoS One ; 18(11): e0288105, 2023.
Article em En | MEDLINE | ID: mdl-38019763
This study examined the association of various brands of NIOSH-certified N95 filtering face-piece respirators (FFR) fit with facial dimensions and gender. One hundred and thirty-five participants (77 females and 58 males) were recruited from the previous facial anthropometry study among Malaysians in 2020. Quantitative respirator fit testing of six FFR were performed using the TSI Portacount Pro+ 8038 which comprised of four exercises (bending over, talking, up-down head movement, and side to side head movement). An overall fit factor (FF) of ≥ 100 was considered a pass for each FFR. Analysis was done using T-test, Pearson's correlations, and generalised linear regression. The passing rates for the six FFR were 36.3% (Cup B), 50.4% (Trifold A), 54.1% (Duckbill A), 57.0% (Cup A), 74.1% (Trifold B), and 83.7% (Duckbill B). Both Duckbill B and Trifold B had the highest passing rates for both genders. However, certain FFR models (Cup B, Trifold A, Trifold B, and Duckbill A) fit better for participants with large facial size who were mostly males, while others (Cup A and Duckbill B) specifically fit better for those with small facial size, who were mostly females. This study showed significant positive effect of nose protrusion, nasal root and subnasale-sellion and the negative effect of menton-sellion, bigonial breadth and nose breadth on fit factors of various FFR. The results of this study emphasized the importance of choosing and designing FFR based on local anthropometry data, with careful consideration on the dimensions that affect the respirator fit. Since N95 are commonly used in the healthcare settings to prevent airborne transmission, the practice of respirator fit testing and selecting N95 with high passing rates for healthcare workers need to be emphasized.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Exposição Ocupacional Limite: Female / Humans / Male Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Malásia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Proteção Respiratória / Exposição Ocupacional Limite: Female / Humans / Male Idioma: En Revista: PLoS One Assunto da revista: CIENCIA / MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Malásia País de publicação: Estados Unidos