Your browser doesn't support javascript.
loading
Biomedical analysis of four fixation systems in treatment of type II traumatic spondylolisthesis of the axis: a finite element analysis.
Long, Zuoyao; Yu, Hailong; Yang, Huifeng; Guo, Mingming; Meng, Lingzhi; Yuan, Hong; Xiang, Liangbi; Wang, Qi.
Afiliação
  • Long Z; General Hospital of Northern Theater Command, Shenyang, China.
  • Yu H; General Hospital of Northern Theater Command, Shenyang, China.
  • Yang H; General Hospital of Northern Theater Command, Shenyang, China.
  • Guo M; General Hospital of Northern Theater Command, Shenyang, China.
  • Meng L; General Hospital of Northern Theater Command, Shenyang, China.
  • Yuan H; General Hospital of Northern Theater Command, Shenyang, China.
  • Xiang L; General Hospital of Northern Theater Command, Shenyang, China. xiangliangbi1963@163.com.
  • Wang Q; General Hospital of Northern Theater Command, Shenyang, China. ven15@126.com.
Med Biol Eng Comput ; 62(3): 843-852, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38052881
This study aimed to compare the properties and safety of self-designed plates in type II traumatic spondylolisthesis of the axis with those of traditional devices via finite element (FE) analysis. We constructed a hangman's fracture FE model from the occipital bone (C0) level to the C3 level. Then, FE models were constructed for the following four fixation systems: an anterior cervical L-shaped plate with four vertebral screws (4-ACLP), or six screws (6-ACLP), an anterior cervical orion plate (ACOP), and a posterior fixation system. A preloaded compressive force of 50 N and a moment of 1.5 N·m were applied to each model under six working conditions. The mobility of the C2/3 segment decreased significantly in four fixation models. In the Mises stress cloud diagram, 4-ACLP showed a better stress distribution in both the bone graft and fixation system than 6-ACLP and ACOP. The resultant force of 4-ACLP was lower but higher than ACOP in axial force. Additionally, the cage in the 4-ACLP configuration experienced the highest stress in the six working conditions. Hence, this novel self-designed plate has the potential to mitigate the operational difficulties, provide sufficient stability, reduce the risk of plate or screw fractures, and improve bone fusion.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espondilolistese / Fraturas da Coluna Vertebral / Fraturas Ósseas Limite: Humans Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espondilolistese / Fraturas da Coluna Vertebral / Fraturas Ósseas Limite: Humans Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos