Your browser doesn't support javascript.
loading
Assessment of Ground Contact Time in the Field: Evaluation of Validity and Reliability.
Weber, Jason A; Hart, Nicolas H; Rantalainen, Timo; Connick, Mark; Newton, Robert U.
Afiliação
  • Weber JA; UWA Tech and Policy Lab, University of Western Australia, Perth, Australia.
  • Hart NH; Exercise Medicine Research Institute, Edith Cowan University, Perth, Australia.
  • Rantalainen T; Human Performance Research Centre, University of Technology Sydney, Sydney, Australia.
  • Connick M; Caring Futures Institute, College of Nursing and Health Sciences, Flinders University, Adelaide, Australia.
  • Newton RU; Centre for Healthcare Translation, Queensland University of Technology, Brisbane, Australia.
J Strength Cond Res ; 38(1): e34-e39, 2024 Jan 01.
Article em En | MEDLINE | ID: mdl-38085634
ABSTRACT
ABSTRACT Weber, JA, Hart, NH, Rantalainen, T, Connick, M, and Newton, RU. Assessment of ground contact time in the field evaluation of validity and reliability. J Strength Cond Res 38(1) e34-e39, 2024-The capacity to measure the kinetic and kinematic components of running has been extensively investigated in laboratory settings. Many authors have produced work that is of high value to practitioners within sporting environments; however, the lack of field-based technology to assess features of running gait validly and reliably has prevented the application of these valuable works. This paper examines the validity and reliability of a practical field-based methodology for using commercial inertial measurement units (IMUs) to assess ground contact time (GCT). Validity was examined in the comparison of GCT measured from ground reaction force by a force plate and that determined by a lumbar mounted commercial IMU and analyzed using a commercially available system (SPEEDSIG). Reliability was assessed by a field-based examination of within and between-session variability in GCT measured using a commercially available system (SPEEDSIG). Significance was set at p ≤ 0.05. Results for validity (intraclass correlation [ICC] 0.83) and reliability (ICC 0.91) confirm that the described field-based methodology is qualified for use to determine GCT in a practical setting. The implications of this study are important as they offer sport practitioners (S&C coaches, rehab specialists, and physios) a scalable method to assess GCT in the field to develop greater understanding of their athletes and improve performance, injury prevention, and rehabilitation interventions. Furthermore, these results provide the foundation for further work that could provide greater detail describing individual running gait in the field.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Marcha Limite: Humans Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corrida / Marcha Limite: Humans Idioma: En Revista: J Strength Cond Res Assunto da revista: FISIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália