Sonochemical synthesis of lanthanum ferrite nanoparticle-decorated carbon nanotubes for simultaneous electrochemical determination of acetaminophen and dopamine.
Alkahtani, Saad A; Mahmoud, Ashraf M; Ali, Ramadan; El-Wekil, Mohamed M.
Afiliação
  • Alkahtani SA; Department of Clinical Pharmacy, College of Pharmacy, Najran University, Najran, Saudi Arabia.
  • Mahmoud AM; Department of Pharmaceutical Chemistry, College of Pharmacy, Najran University, Najran, Saudi Arabia.
  • Ali R; Department of Pharmaceutical Chemistry, FacultyofPharmacy, University of Tabuk, 71491, Tabuk, Saudi Arabia. r_ali@ut.edu.sa.
  • El-Wekil MM; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Al Azhar University, Assiut Branch, Asyut, 71526, Egypt. r_ali@ut.edu.sa.
Mikrochim Acta ; 191(1): 25, 2023 12 13.
Article em En | MEDLINE | ID: mdl-38091119
ABSTRACT
A new nanocomposite consisting of lanthanum ferrite nanoparticles (LaFeO3 NPs) integrated with carbon nanotubes (CNTs) was fabricated via facile sonochemical approach. The engineered nanocomposite was applied to simultaneously determine acetaminophen (ACP) and dopamine (DA) in a binary mixture. The LaFeO3 NPs@CNT probe possesses several advantages such as superior conductivity, large surface area, and more active sites, improving its electrocatalytic activity towards ACP and DA. Under optimized conditions, the anodic peak currents (Ipa) linearly increased with increasing concentration of ACP and DA in the range 0.069-210 µM and 0.15-210 µM, respectively. The sensitivity of LaFeO3 NPs@CNTs/glassy carbon electrode (GCE) for detecting ACP and DA is 7.456 and 5.980 µA·µM-1·cm-2, respectively. The detection limits (S/N = 3) for ACP and DA are 0.02 µM and 0.05 µM, respectively. Advantages of LaFeO3 NPs@CNTs/GCE for the detection of ACP and DA include wide linear ranges, low-detection limits, good selectivity, and long-term stability. The as-fabricated electrode was applied to determine ACP and DA in pharmaceutical formulations and human serum samples with recoveries ranging from 97.7 to 103.3% and an RSD that did not exceed 3.7%, confirming the suitability of the proposed sensor for the determination of ACP and DA in real samples. This study not only presents promising opportunities for enhancing the sensitivity and stability of electrochemical sensors used in the detection of bioanalytes but also significantly contributes to the progress of unique and comprehensive biochemical detection methodologies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Nanopartículas Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Arábia Saudita País de publicação: AT / AUSTRIA / ÁUSTRIA

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanotubos de Carbono / Nanopartículas Limite: Humans Idioma: En Revista: Mikrochim Acta Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Arábia Saudita País de publicação: AT / AUSTRIA / ÁUSTRIA