Your browser doesn't support javascript.
loading
Hybrid Radiant Disinfection: Exploring UVC and UVB Sterilization Impact on the Mechanical Characteristics of PLA Materials.
Aboamer, Mohamed A; Alsuayri, Ahmed S; Alassaf, Ahmad; Alqahtani, Tariq M; Alresheedi, Bakheet A; Saijari, Ghazwan N; Osman, Elamir A; Mohamed, Nader A Rahman.
Afiliação
  • Aboamer MA; Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia.
  • Alsuayri AS; Erada and Mental Health Hospital, Al-Kharj 16246, Saudi Arabia.
  • Alassaf A; Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia.
  • Alqahtani TM; Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia.
  • Alresheedi BA; Department of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Majmaah 11952, Saudi Arabia.
  • Saijari GN; Department of Preventive Dental Science, College of Dentistry, Majmaah University, Majmaah 11952, Saudi Arabia.
  • Osman EA; Biomedical Technology Department, Inaya Medical Colleges, Riyadh 13541, Saudi Arabia.
  • Mohamed NAR; Biomedical Engineering Department, Faculty of Engineering, Misr University for Science and Technology (MUST), Giza 12568, Egypt.
Polymers (Basel) ; 15(24)2023 Dec 10.
Article em En | MEDLINE | ID: mdl-38139910
ABSTRACT
This study explores the impact of disinfection techniques on the mechanical properties of poly(lactic acid) (PLA), a crucial material in the production of medical implants, tissue engineering, orthopedic devices and drug delivery systems, owing to its biocompatibility and ease of manufacturing. The focus is on evaluating the effectiveness of ultraviolet (UV) type C (254 nm wavelength) and the combined use of type C and B (310 nm wavelength) disinfection methods. Fifteen tensile test specimens (ASTM D638) and fifteen compression test specimens (ASTM D695) were utilized to assess PLA's mechanical properties, including yield strength, ultimate strength, and fracture strength. The investigation involved subjecting the specimens to the specified disinfection methods and evaluating these properties both before and after the disinfection process. In the tensile test, a statistically significant difference (p = 0) in yield displacement was observed among the three groups. Additionally, a notable difference (p = 0.047) in fracture displacement was identified between the untreated group and the UVC and UVB combination group. No discernible impact on yield or fracture forces was noted. In the compression test, there was a significant difference (p = 0.04) in yield displacement and a clear difference (p = 0.05) in fracture force between the untreated group and the UVC and UVB combination group. The hybrid combination of UVC and UVB disinfection techniques did not affect yield force in both tensile and compression tests. However, it demonstrated a clear impact on displacement, suggesting its potential as a promising disinfection technique in the medical field.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Arábia Saudita

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Polymers (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Arábia Saudita
...