STGA-MS: AI diagnosis model of regional wall motion abnormality based on 2D transthoracic echocardiography.
Heliyon
; 10(1): e23224, 2024 Jan 15.
Article
em En
| MEDLINE
| ID: mdl-38163158
ABSTRACT
Regional wall motion abnormality (RWMA) is a common manifestation of ischemic heart disease detected through echocardiography. Currently, RWMA diagnosis heavily relies on visual assessment by doctors, leading to limitations in experience-based dependence and suboptimal reproducibility among observers. Several RWMA diagnosis models were proposed, while RWMA diagnosis with more refined segments can provide more comprehensive wall motion information to better assist doctors in the diagnosis of ischemic heart disease. In this paper, we proposed the STGA-MS model which consists of three modules, the spatial-temporal grouping attention (STGA) module, the segment feature extraction module, and the multiscale downsampling module, for the diagnosis of RWMA for multiple myocardial segments. The STGA module captures global spatial and temporal information, enhancing the representation of myocardial motion characteristics. The segment feature extraction module focuses on specific segment regions, extracting relevant features. The multiscale downsampling module analyzes myocardial motion deformation across different receptive fields. Experimental results on a 2D transthoracic echocardiography dataset show that the proposed STGA-MS model achieves better performance compared to state-of-the-art models. It holds promise in improving the accuracy and reproducibility of RWMA diagnosis, assisting clinicians in diagnosing ischemic heart disease more reliably.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Idioma:
En
Revista:
Heliyon
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
China