Your browser doesn't support javascript.
loading
The early postoperative effects of rinsing the breast pocket with tranexamic acid in prepectoral prosthetic breast reconstruction.
Bae, Juyoung; Lee, Dianne Dong Un; Lee, Kyeong-Tae; Pyon, Jai Kyong; Jeon, Byung-Joon; Mun, Goo-Hyun.
Afiliação
  • Bae J; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Lee DDU; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Lee KT; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Pyon JK; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Jeon BJ; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Mun GH; Department of Plastic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Electronic address: supramicro@gmail.com.
J Plast Reconstr Aesthet Surg ; 89: 125-133, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38181633
ABSTRACT

BACKGROUND:

The efficacy of tranexamic acid (TXA) has been reported in breast surgery; however, its application and duration have varied across studies. This study aimed to assess the early postoperative outcomes of rinsing the breast pocket with TXA during prepectoral prosthetic breast reconstruction using an acellular dermal matrix (ADM).

METHODS:

A retrospective chart review was conducted in consecutive patients who underwent immediate prosthetic prepectoral reconstruction between August 2021 and December 2022. For cases performed during the earlier part of the study period (up to April 2022), TXA was not administered (non-TXA group), whereas those performed after April 2022 received topical TXA application during surgery (TXA group). Postoperative outcomes including hematoma, seroma, drainage volume, and drain maintenance duration were compared between the two groups using propensity score matching (PSM).

RESULTS:

A total of 674 breasts were analyzed; 280 in the TXA group and 394 were in the non-TXA group. There were 251 breasts in each group after PSM, and their characteristics were similar. The incidence of hematoma in the first 24 hours and total drain output were significantly lower in the TXA group than the non-TXA group. In cases of direct-to-implant cases, the TXA group showed a significantly lower seroma rate.

CONCLUSIONS:

Rinsing the breast pocket with TXA can potentially reduce the occurrence of hematoma and decrease drain output in prepectoral ADM-assisted prosthetic breast reconstruction. Moreover, this approach may be beneficial in lowering the incidence of seroma in direct-to-implant reconstruction.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Tranexâmico / Neoplasias da Mama / Mamoplastia / Implantes de Mama / Implante Mamário / Derme Acelular Limite: Female / Humans Idioma: En Revista: J Plast Reconstr Aesthet Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Tranexâmico / Neoplasias da Mama / Mamoplastia / Implantes de Mama / Implante Mamário / Derme Acelular Limite: Female / Humans Idioma: En Revista: J Plast Reconstr Aesthet Surg Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Holanda