Your browser doesn't support javascript.
loading
The effects of 3D/Full HD and 2D/Ultra HD imaging systems on suturing skills during total laparoscopic hysterectomy: a prospective cohort study.
Tercan, Can; Sivas, Mustafa Can; Aktoz, Fatih.
Afiliação
  • Tercan C; Department of Obstetrics and Gynecology, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey. cntrcn89@gmail.com.
  • Sivas MC; Department of Obstetrics and Gynecology, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
  • Aktoz F; Women's Health Center, American Hospital, Istanbul, Turkey.
Arch Gynecol Obstet ; 309(3): 1027-1033, 2024 03.
Article em En | MEDLINE | ID: mdl-38184803
ABSTRACT

PURPOSE:

2D/Ultra HD and 3D/Full HD imaging systems can provide surgeons with more accurate and detailed views of the surgical site. We aimed to compare the effects of 2D/Ultra HD and 3D/Full HD laparoscopy systems on laparoscopic suturing skills during total laparoscopic hysterectomy.

METHODS:

In this prospective cohort study, patients were recruited from a tertiary hospital, and demographic data and surgical data were recorded. The primary outcome measures were the durations of the total operation and vaginal cuff closure. Secondary outcome measures were colpotomy duration, total number of sutures placed, duration of first, second, third and fourth sutures, mean suturing duration, total operation duration, the surgeon's perception of difficulty during the vaginal cuff suturing and complications.

RESULTS:

The 3D/Full HD (n = 39) and 2D/Ultra HD (n = 42) groups were compared in terms of age, BMI, number of previous abdominal surgeries, number of previous cesarean sections, and type of delivery were examined. Both groups were considered homogeneous. The 3D/Full HD group was found to be superior in terms of colpotomy duration, duration of the first, second, and third suture, mean suturing duration, vaginal cuff closure duration, and difficulty of use compared to 2D/Ultra HD group (p < 0.05 for all).

CONCLUSION:

In conclusion, the use of 3D/Full HD laparoscopy systems can lead to improved surgical outcomes in terms of colpotomy duration, duration of the first, second, and third suture, mean suturing duration, vaginal cuff closure duration, and difficulty of use compared to 2D/Ultra HD systems.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Sutura / Laparoscopia Tipo de estudo: Etiology_studies / Observational_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Sutura / Laparoscopia Tipo de estudo: Etiology_studies / Observational_studies Limite: Female / Humans / Pregnancy Idioma: En Revista: Arch Gynecol Obstet Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia País de publicação: Alemanha