Anatomic pattern of perforator arteries from proper digital arteries in human triphalangeal digits.
Navío-Fernández, Fernando; Corella, Fernando; Ocampos, Montserrat; Pastor-Fernández, Esther; Vázquez, Teresa.
Afiliação
  • Navío-Fernández F; Orthopaedic and Trauma Department, Hospital Francesc de Borja, Av. de la Medicina 6, Gandía, 46702, Valencia, Spain.
  • Corella F; Orthopedic and Trauma Department, Hospital Universitario Infanta Leonor, Madrid, Spain; Hand Surgery Unit, Hospital Universitario Quironsalud Madrid, Madrid, Spain; Surgery Department, School of Medicine, Complutense University of Madrid, Madrid, Spain. Electronic address: fernando.corella@gmail.com
  • Ocampos M; Orthopedic and Trauma Department, Hospital Universitario Infanta Leonor, Madrid, Spain; Hand Surgery Unit, Hospital Universitario Quironsalud Madrid, Madrid, Spain.
  • Pastor-Fernández E; Orthopaedic and Trauma Department, Hospital Francesc de Borja, Av. de la Medicina 6, Gandía, 46702, Valencia, Spain.
  • Vázquez T; Human Anatomy and Embryology Department, School of Medicine, Complutense University of Madrid, Madrid, Spain.
Injury ; 54 Suppl 7: 111062, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38225164
ABSTRACT

INTRODUCTION:

The localization of the perforator artery for the performance of digital artery perforator (DAP) flaps poses a challenge. This study aims to describe the anatomical pattern of the perforator arteries originating from the proper digital artery in fresh cadaveric triphalangeal digits and to use this pattern as a point of reference for performing these flaps. MATERIAL AND

METHOD:

We performed a descriptive anatomical study on 28 fresh cadaveric hands (14 male, 14 female; 10 right hands, 18 left hands) after injecting the arterial system with latex. Digital photographs were taken of each specimen after dissection and the number of perforator arteries in each finger (second to fifth), phalanx (proximal, middle and distal) and finger side (radial or ulnar) were obtained by analysis in Adobe Photoshop CS6.

RESULTS:

We obtained statistically significant results when comparing the means of the number of perforator arteries between fingers, phalanx, finger side, gender and laterality. When analyzing the number of perforator arteries in each phalanx third in each finger, we found that more than 75% of specimens had at least one perforator artery in the two distal thirds of the proximal phalanx and the three-thirds of the middle phalanx and more than 50% had at least one in the proximal third of the distal phalanx.

CONCLUSIONS:

We present a homogeneous perforator artery anatomic pattern, by finger, phalanx, finger side, gender and laterality, consisting of a high density of perforator arteries in the distal proximal phalanx region, throughout the middle phalanx and in the proximal distal phalanx region, which would be the areas of greatest certainty to help predict the favorable evolution of a digital artery perforator flap in the fingers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retalho Perfurante / Traumatismos dos Dedos Limite: Female / Humans / Male Idioma: En Revista: Injury Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Retalho Perfurante / Traumatismos dos Dedos Limite: Female / Humans / Male Idioma: En Revista: Injury Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Espanha