Your browser doesn't support javascript.
loading
A rapid and simple HPLC-MS/MS method for the therapeutic drug monitoring of six special-grade antimicrobials in pediatric patients.
Jiang, Xijuan; Qin, Yabin; Lei, Rong; Han, Yu; Yang, Jing; Zhang, Guying; Liu, Jianfang.
Afiliação
  • Jiang X; Department of Pharmacy, Hebei Children's Hospital, Shijiazhuang, Hebei, 050031, China.
  • Qin Y; Department of Pharmacy, Hebei Children's Hospital, Shijiazhuang, Hebei, 050031, China.
  • Lei R; Hebei Key Laboratory of Traditional Chinese Medicine Quality Evaluation and Standard Research, Hebei Institute for Drug and Medical Device Control, Shijiazhuang, Hebei, 050227, China.
  • Han Y; Department of Pharmacy, Hebei Children's Hospital, Shijiazhuang, Hebei, 050031, China.
  • Yang J; Department of Pharmacy, Hebei Children's Hospital, Shijiazhuang, Hebei, 050031, China.
  • Zhang G; Department of Pharmacy, Hebei Children's Hospital, Shijiazhuang, Hebei, 050031, China.
  • Liu J; Office of Clinical Trial Center, The First Affiliated Hospital of Hebei University of Chinese Medicine, Shijiazhuang, Hebei, 050017, China.
Heliyon ; 10(1): e24198, 2024 Jan 15.
Article em En | MEDLINE | ID: mdl-38226205
ABSTRACT
Meropenem, linezolid, fluconazole, voriconazole, posaconazole, and vancomycin are six important antimicrobials used for severe infections in critically ill patients listed in special-grade antimicrobials in China. The six antimicrobials' highly variable pharmacodynamics and pharmacokinetics in critically ill pediatric patients present significant challenges to clinicians in ensuring optimal therapeutic targets. Therefore, therapeutic drug monitoring of these antimicrobials in human plasma is necessary to obtain their plasma concentration. A rapid, simple, and sample-saving high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed, which could simultaneously determine all six antimicrobials. It required only 10 µL of plasma and a one-step protein precipitation process. Chromatographic separation was achieved on a reversed-phase column (C18, 30 × 2.1 mm, 2.6 µm) via gradient elution using water and acetonitrile containing 0.1 % formic acid as mobile phase. The injection volume was 2 µL, and the total run time was only 2.5 min. Detection was done using a Triple Quad™ 4500MD tandem mass spectrometer coupled with an electrospray ionization (ESI) source in positive mode. The calibration curves ranged from 0.5 to 64 µg/mL for meropenem and fluconazole, 0.2-25.6 µg/mL for linezolid and voriconazole, 0.1-12.8 µg/mL for posaconazole and 1-128 µg/mL for vancomycin, with the coefficients of correlation all greater than 0.996. Furthermore, the method was validated rigorously according to the European Medicines Agency (EMA) guidelines, demonstrating excellent accuracy (from 93.0 % to 110.6 %) and precision (from 2.0 % to 12.8 %). Moreover, its applicability to various matrices (including serum, hemolytic plasma, and hyperlipidemic plasma) was evaluated. Thus, this method was successfully applied to routine therapeutic drug monitoring for critically ill pediatric patients and other patients in need.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China