Your browser doesn't support javascript.
loading
A Label-Free Aptasensor for Turn-On Fluorescent Detection of Aflatoxin B1 Based on an Aggregation-Induced-Emission-Active Probe and Single-Walled Carbon Nanohorns.
Yang, Huanhuan; Lv, Lei; Niu, Mengyu; Zhang, Dongjie; Guo, Zhijun.
Afiliação
  • Yang H; College of Food Science, Heilongjiang Bayi Agricultural University, Daqing 163000, China.
  • Lv L; College of Life Science, Changchun Normal University, Changchun 130032, China.
  • Niu M; College of Agriculture, Yanbian University, Yanji 133002, China.
  • Zhang D; College of Agriculture, Yanbian University, Yanji 133002, China.
  • Guo Z; College of Food Science, Heilongjiang Bayi Agricultural University, Daqing 163000, China.
Foods ; 12(23)2023 Dec 01.
Article em En | MEDLINE | ID: mdl-38231791
ABSTRACT
The determination of the aflatoxin B1 (AFB1) content has received widespread attention in the context of food safety, which is a global public health issue. Accordingly, a label-free and turn-on fluorescent AFB1 determination method is developed herein with an ss-DNA aptamer as the recognition element, 4, 4-(1E,1E)-2, 2-(anthracene-9, 10-diyl) bis(ethene-2, 1-diyl) bis(N, N, N-trimethylbenzenaminium iodide) (DSAI) as the aggregation-induced emission (AIE) fluorescent probe, and single-walled carbon nanohorns (SWCNHs) as the selective part with a fluorescence quenching effect. In the presence of AFB1, the AFB1-specific aptamer undergoes a structural transformation and switches from being a random helix to a folded structure. DSAI's fluorescence is protected as a result of the resistance of the transformed aptamer adsorbed on the SWCNHs' surface. Because DSAI's fluorescence is not quenchable, the fluorescence intensity is calculated as a function of the AFB1 concentration. By simply mixing DSAI, aptamer, AFB1 samples, and SWCNHs, the method can be carried out in 2 h, with a limit of detection (LOD) of 1.83 ng/mL. It has a high selectivity in the presence of other mycotoxins, and its performance is confirmed in soybean sauce with a known concentration of AFB1. The LOD was 1.92 ng/mL in the soy sauce samples and the recovery ranged from 95 to 106%, implying that the presented aptasensor has great potential for food analysis.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Foods Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Foods Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China
...