Novel method for determining when a field-collected donor unit is sufficiently full.
Yazer, Mark H; Werneiwski, Kendall; Thompson, Patrick; Titlestad, Kjell; Watkins, Thomas; Smith, Stephen; Bengtsson, Jesper; Brunetta, Denise M; Carlos, Luciana; Jenkins, Donald; Salcido, Julian; Ngamsuntikul, Samantha G; Taye, Habetamu; Kinfu, Abiy; Tadesse, Demewoz; Jackson, Bryon P; Kutner, José; Yokoyama, Ana Paula; Hess, John R; Tuott, Erin; Ilmakunnas, Minna; de Regt, Ann K; Wiebke, Handke; Seltsam, Axel; Braverman, Maxwell; Compton, Frances; Sutor, Laurie; Meledeo, Michael A; Messenger, Jacquelyn M; DePasquale, Marc.
Afiliação
  • Yazer MH; Department of Pathology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
  • Werneiwski K; School of Medicine, Biomedical Master's Program, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
  • Thompson P; Atem, Andover, UK.
  • Titlestad K; Department of Clinical Immunology, University of Southern Denmark, Odense, Denmark.
  • Watkins T; Medic Regional Blood Center, Knoxville, Tennessee, USA.
  • Smith S; Medic Regional Blood Center, Knoxville, Tennessee, USA.
  • Bengtsson J; Department of Clinical Immunology and Transfusion Medicine, Laboratory Medicine, Office for Medical Services, Region Skåne, Lund, Sweden.
  • Brunetta DM; Centro de Hematologia e Hemoterapia do Ceara, HEMOCE, Fortaleza, Brazil.
  • Carlos L; Complexo Hospitalar da Universidade Federal do Ceará, Transfusion Unit, Fortaleza, Brazil.
  • Jenkins D; Centro de Hematologia e Hemoterapia do Ceara, HEMOCE, Fortaleza, Brazil.
  • Salcido J; Instituto Dr Jose Frota, Transfusion Unit, Fortaleza, Brazil.
  • Ngamsuntikul SG; Department of Surgery, The University of Texas Southwestern Medical Center, San Antonio, Texas, USA.
  • Taye H; BioBridge Global, San Antonio, Texas, USA.
  • Kinfu A; BioBridge Global, San Antonio, Texas, USA.
  • Tadesse D; Ethiopian Blood and Tissue Bank service, Addis Ababa, Ethiopia.
  • Jackson BP; Ethiopian Blood and Tissue Bank service, Addis Ababa, Ethiopia.
  • Kutner J; Ethiopian Blood and Tissue Bank service, Addis Ababa, Ethiopia.
  • Yokoyama AP; Department of Pathology, University of Maryland School of Medicine, Baltimore, Maryland, USA.
  • Hess JR; Hemotherapy and Cell Therapy Department, Hospital Israelita Albert Einstein, São Paulo, Brazil.
  • Tuott E; Hemotherapy and Cell Therapy Department, Hospital Israelita Albert Einstein, São Paulo, Brazil.
  • Ilmakunnas M; Department of Laboratory Medicine and Pathology, University of Washington School of Medicine, Seattle, Washington, USA.
  • de Regt AK; Department of Laboratory Medicine and Pathology, University of Washington School of Medicine, Seattle, Washington, USA.
  • Wiebke H; Department of Anesthesiology and Intensive Care Medicine, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
  • Seltsam A; Finnish Red Cross Blood Service, Helsinki, Finland.
  • Braverman M; Bavarian Red Cross Blood Service, Nuremberg, Germany.
  • Compton F; Bavarian Red Cross Blood Service, Nuremberg, Germany.
  • Sutor L; Bavarian Red Cross Blood Service, Nuremberg, Germany.
  • Meledeo MA; Department of Surgery, St. Luke's University Health Network, Bethlehem, Pennsylvania, USA.
  • Messenger JM; Carter BloodCare, Bedford, Texas, USA.
  • DePasquale M; Carter BloodCare, Bedford, Texas, USA.
Transfusion ; 64 Suppl 2: S27-S33, 2024 May.
Article em En | MEDLINE | ID: mdl-38251751
ABSTRACT

BACKGROUND:

Whole blood (WB) collections can occur downrange for immediate administration. An important aspect of these collections is determining when the unit is sufficiently full. This project tested a novel method for determining when a field collection is complete.

METHODS:

The amount of empty space at the top of WB units, destined to become LTOWB or separated into components, that were collected at blood centers or hospitals was measured by holding a WB unit off the ground and placing the top of a piece of string where the donor tubing entered the bag. The string was marked where it intersected the top of the column of blood in the bag and measured from the top. The WB units were also weighed.

RESULTS:

A total of 15 different bags, two of which were measured in two different filling volumes, from 15 hospitals or blood centers were measured and weighed. The most commonly used blood bag, Terumo Imuflex SP, had a median string length of 9 mm (range 2-24 mm) and weighed a median of 565.1 g (range 524.8-636.7 g).

CONCLUSION:

Pieces of string can be precut to the appropriate length depending on the type of bag before a mission where field WB collections might be required and a mark placed on the bag before the collection commences to indicate when the unit is full.