Your browser doesn't support javascript.
loading
Enhanced Sensitivity of Electrochemical Sensors for Ammonia-Nitrogen via In-Situ Synthesis PtNi Nanoleaves on Carbon Cloth.
Wang, Guanda; Ma, Guoxing; Gao, Jie; He, Dong; Zhao, Chun; Suo, Hui.
Afiliação
  • Wang G; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • Ma G; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • Gao J; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • He D; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • Zhao C; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
  • Suo H; State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012, China.
Sensors (Basel) ; 24(2)2024 Jan 09.
Article em En | MEDLINE | ID: mdl-38257480
ABSTRACT
Pt-based electrochemical ammonia-nitrogen sensors played a significance role in real-time monitoring the ammonia-nitrogen concentration. The alloying of Pt and transition metals was one of the effective ways to increase the detectability of the sensitive electrode. In this paper, a self-supported electrochemical electrode for the detection of ammonia nitrogen was obtained by the electrodeposition of PtNi alloy nanoleaves on a carbon cloth (PtNi-CC). Experimental results showed that the PtNi-CC electrode exhibited enhanced detection performance with a wide linear range from 0.5 to 500 µM, high sensitivity (7.83 µA µM-1 cm-2 from 0.5 to 150 µM and 0.945 µA µM-1 cm-2 from 150 to 500 µM) and lower detection limit (24 nM). The synergistic effect between Pt and Ni and the smaller lattice spacing of the PtNi alloy were the main reasons for the excellent performance of the electrode. This work showed the great potential of Pt-based alloy electrodes for the detection of ammonia-nitrogen.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China