Your browser doesn't support javascript.
loading
Development and validation of nomograms using photoacoustic imaging and 2D ultrasound to predict breast nodule benignity and malignancy.
Chen, Jing; Huang, Zhibin; Luo, Hui; Li, Guoqiu; Ding, Zhimin; Tian, Hongtian; Tang, Shuzhen; Mo, Sijie; Xu, Jinfeng; Wu, Huaiyu; Dong, Fajin.
Afiliação
  • Chen J; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Huang Z; Ultrasound Department, The Second Clinical Medical College, Jinan University, Shenzhen, Guangdong 518020, China.
  • Luo H; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Li G; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Ding Z; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Tian H; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Tang S; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Mo S; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Xu J; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Wu H; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
  • Dong F; Ultrasound Department, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University; The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, Guangdong 518020, China.
Postgrad Med J ; 100(1183): 309-318, 2024 Apr 22.
Article em En | MEDLINE | ID: mdl-38275274
ABSTRACT

BACKGROUND:

The application of photoacoustic imaging (PAI), utilizing laser-induced ultrasound, shows potential in assessing blood oxygenation in breast nodules. However, its effectiveness in distinguishing between malignant and benign nodules remains insufficiently explored.

PURPOSE:

This study aims to develop nomogram models for predicting the benign or malignant nature of breast nodules using PAI.

METHOD:

A prospective cohort study enrolled 369 breast nodules, subjecting them to PAI and ultrasound examination. The training and testing cohorts were randomly divided into two cohorts in a ratio of 31. Based on the source of the variables, three models were developed, Model 1 photoacoustic-BIRADS+BMI + blood oxygenation, Model 2 BIRADS+Shape+Intranodal blood (Doppler) + BMI, Model 3 photoacoustic-BIRADS+BIRADS+ Shape+Intranodal blood (Doppler) + BMI + blood oxygenation. Risk factors were identified through logistic regression, resulting in the creation of three predictive models. These models were evaluated using calibration curves, subject receiver operating characteristic (ROC), and decision curve analysis.

RESULTS:

The area under the ROC curve for the training cohort was 0.91 (95% confidence interval, 95% CI 0.88-0.95), 0.92 (95% CI 0.89-0.95), and 0.97 (95% CI 0.96-0.99) for Models 1-3, and the ROC curve for the testing cohort was 0.95 (95% CI 0.91-0.98), 0.89 (95% CI 0.83-0.96), and 0.97 (95% CI 0.95-0.99) for Models 1-3.

CONCLUSIONS:

The calibration curves demonstrate that the model's predictions agree with the actual values. Decision curve analysis suggests a good clinical application.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Nomogramas / Técnicas Fotoacústicas Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Postgrad Med J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Nomogramas / Técnicas Fotoacústicas Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Postgrad Med J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China
...