Combining Potential Strain Elastography and Radiomics for Diagnosing Breast Lesions in BI-RADS 4: Construction and Validation a Predictive Nomogram.
Zha, Hailing; Wu, Tingting; Zhang, Manqi; Cai, Mengjun; Diao, Xuehong; Li, Fang; Wu, Rong; Du, Yu.
Afiliação
  • Zha H; Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Wu T; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Zhang M; Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China.
  • Cai M; Department of Ultrasound, Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China.
  • Diao X; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Li F; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Wu R; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Du Y; Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Electronic address: duyu_edu1989@163.com.
Acad Radiol ; 31(8): 3106-3116, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38378324
ABSTRACT
RATIONALE AND

OBJECTIVES:

To develop a nomogram by integrating B-mode ultrasound (US), strain ratio (SR), and radiomics signature (RS) effectively differentiating between benign and malignant lesions in the Breast Imaging Reporting and Data System (BI-RADS) 4. MATERIALS AND

METHODS:

We retrospectively recruited 709 consecutive patients who were assigned a BI-RADS 4 and underwent curative resection or biopsy between 2017 and 2022. US images were collected before surgery. A RS was developed through a multistep feature selection and construction process. Histology findings served as the gold standard. Univariate and multivariate regression analysis were employed to analyze the clinical and US characteristics and identify variables for developing a nomogram. The calibration and discrimination of the nomogram were conducted to evaluate its performance.

RESULTS:

The study included a total of 709 patients, with 497 in the training set and 212 in the validation set. In the training set, the B-mode US had an AUC of 0.84 (95% confidence interval [CI], 0.80, 0.87). The SR demonstrated an AUC of 0.78 (95% CI, 0.74, 0.82), while the RS showed an AUC of 0.85 (95% CI, 0.81, 0.88). Notably, the nomogram exhibited superior performance compared to the conventional US, SR, and RS (AUC=0.93, both p < 0.05, as per the Delong test). The clinical usefulness of the nomogram was favorable.

CONCLUSION:

The calibrated nomogram can be specifically designed to predict the malignancy of breast lesions in the BI-RADS 4 category.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Nomogramas / Técnicas de Imagem por Elasticidade Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Ultrassonografia Mamária / Nomogramas / Técnicas de Imagem por Elasticidade Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: Acad Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Estados Unidos