Your browser doesn't support javascript.
loading
Caliper-Based Restricted Kinematic Alignment Total Knee Arthroplasty.
Okajima, Takahiro; Hiranaka, Takafumi; Fukai, Yasuhiro; Tanaka, Sho; Koide, Motoki; Fujishiro, Takaaki; Okamoto, Koji.
Afiliação
  • Okajima T; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Hiranaka T; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Fukai Y; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Tanaka S; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Koide M; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Fujishiro T; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
  • Okamoto K; Department of Orthopaedic Surgery and Joint Surgery Centre, Takatsuki General Hospital, Takatsuki, JPN.
Cureus ; 16(1): e52780, 2024 Jan.
Article em En | MEDLINE | ID: mdl-38389595
ABSTRACT
Restricted kinematic alignment total knee arthroplasty (rKA-TKA) is a reasonable selection for avoiding an extreme alignment that has been conceded to induce implant failure. However, computer-aided devices (CAS), such as navigation, robotics, and patient-specific instrumentation, are necessary to perform rKA-TKA. This paper reports on the surgical technique of kinematic alignment total knee arthroplasty (KA-TKA) using mechanical instruments. The lateral distal femoral angle (LDFA) and the medial proximal tibial angle (MPTA) are measured from preoperative long radiographs or CT of the lower limb, and the arithmetic hip-knee-ankle angle (aHKA) is calculated from the MPTA - LDFA. The predefined restriction boundaries are used to determine the osteotomy angle. In our practice, the LDFA is 85° to 93°, the MPTA is 85° to 90°, and the aHKA is 5° varus to 3° valgus. If correction of the femoral osteotomy is required, this can be achieved by changing the thickness of the paddle set on the distal articular surface or by adjusting the angle of the variable angle femoral cutting guide. For the tibia, the distal end of the extramedullary rod, with the proximal part placed in the center of the knee joint, should be adjusted so that it does not exceed the lateral malleolus. This limits the medial tilt of the osteotomy plane to within 5.5°. These techniques allow restricted KA to be performed with existing mechanical instruments without using CAS.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Cureus Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos