Your browser doesn't support javascript.
loading
Transcatheter aortic valve replacement planning with cardiac computed tomography in quadricuspid aortic valve stenosis: a case series.
Aquino-Bruno, Heberto; Muratalla-González, Roberto; Garcia-Garcia, Juan F; Triano-Doroteo, José L; Rivera, Kevin Felix; Balcarcel, Gerardo Carreon; Navarrete-Osuna, Marisol.
Afiliação
  • Aquino-Bruno H; Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Av. Felix Cuevas #540, Col. Del Valle Del. Benito Juarez, Mexico City 03100, Mexico.
  • Muratalla-González R; Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Av. Felix Cuevas #540, Col. Del Valle Del. Benito Juarez, Mexico City 03100, Mexico.
  • Garcia-Garcia JF; Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Av. Felix Cuevas #540, Col. Del Valle Del. Benito Juarez, Mexico City 03100, Mexico.
  • Triano-Doroteo JL; Interventional Cardiology Service, Hospital Regional Culiacan ISSSTE, Sinaloa, Mexico.
  • Rivera KF; Interventional Cardiology Service, Hospital Regional Culiacan ISSSTE, Sinaloa, Mexico.
  • Balcarcel GC; Interventional Cardiology Service, Hospital Regional Veracruz ISSSTE, Veracruz, Mexico.
  • Navarrete-Osuna M; Ecocardiography Cardiology Service, Hospital Regional Veracruz ISSSTE, Veracruz, Mexico.
Eur Heart J Case Rep ; 8(2): ytae079, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38405198
ABSTRACT

Background:

The presence of severe aortic stenosis in quadricuspid aortic valve (QAV) is an extremely rare combination, and it is unknown whether transcatheter aortic valve replacement (TAVR) is a safe option due to the low incidence. Case

summary:

We present two patients diagnosed with severe aortic stenosis with QAV morphology type 1 (Nakamura classification). All patients presented to our hospital for evaluation because of worsening functional class, dyspnoea, or syncope. During tomographic planning, the aortic annulus was measured at the level of the deepest sinus for the selection of the number of devices. Due to the presence of four cusps, the smallest cusp was excluded, and three sinuses were virtualized for placement of the pigtail catheter during the procedure. Without complications, a 23 mm Edwards SAPIEN 3 was deployed through the femoral artery in both patients. Control aortography showed no valve leakage or regurgitation.

Discussion:

In patients with QAV and aortic stenosis undergoing TAVR, similar to the tricuspid valve, tomographic planning can be used to ensure the success of the procedure. However, unlike the tricuspid valve, where the selection of the device number is based on the measurements of the aortic annulus at the level of the non-coronary sinus, in these QAV cases, we perform the measurements at the level of the deepest aortic sinus (right coronary sinus).
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Eur Heart J Case Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México