Phase 3 Randomized Clinical Trial of the Safety and Efficacy of Travoprost Intraocular Implant in Patients with Open-Angle Glaucoma or Ocular Hypertension.
Sarkisian, Steven R; Ang, Robert E; Lee, Andy M; Berdahl, John P; Heersink, Sebastian B; Burden, James H; Doan, Long V; Stephens, Kerry G; Kothe, Angela C; Usner, Dale W; Katz, L Jay; Navratil, Tomas.
Afiliação
  • Sarkisian SR; Oklahoma Eye Surgeons, PLLC, Oklahoma City, Oklahoma.
  • Ang RE; Asian Eye Institute, Makati City, Philippines.
  • Lee AM; Total Eye Care, Duncanville, Texas.
  • Berdahl JP; Vance Thompson Vision, Sioux Falls, South Dakota.
  • Heersink SB; Eye Center South, DBA Trinity Research Group, Dothan, Alabama.
  • Burden JH; Skyline Vision Clinic and Laser Center, Colorado Springs, Colorado.
  • Doan LV; Glaukos Corporation, Aliso Viejo, California.
  • Stephens KG; Glaukos Corporation, Aliso Viejo, California.
  • Kothe AC; Glaukos Corporation, Aliso Viejo, California.
  • Usner DW; Glaukos Corporation, Aliso Viejo, California.
  • Katz LJ; Glaukos Corporation, Aliso Viejo, California.
  • Navratil T; Glaukos Corporation, Aliso Viejo, California. Electronic address: tnavratil@glaukos.com.
Ophthalmology ; 2024 Feb 27.
Article em En | MEDLINE | ID: mdl-38423216
ABSTRACT

PURPOSE:

To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of 2 models of the travoprost intraocular implant (fast-eluting [FE] and slow-eluting [SE] types) from 1 of 2 phase 3 trials (the GC-010 trial).

DESIGN:

Multicenter, randomized, double-masked, sham-controlled, noninferiority trial.

PARTICIPANTS:

Patients with open-angle glaucoma or ocular hypertension having an unmedicated baseline mean diurnal IOP (average of 8 am, 10 am, and 4 pm time points) of ≥ 21 mmHg, and IOP of ≤ 36 mmHg at each of the 8 am, 10 am, and 4 pm timepoints at baseline.

METHODS:

Study eyes were randomized to the travoprost intraocular implant (FE implant [n = 200] or SE implant [n = 197] model) or to timolol ophthalmic solution 0.5% twice daily (n = 193). MAIN OUTCOME

MEASURES:

The primary outcome was mean change from baseline IOP in the study eye at 8 am and 10 am, at each of day 10, week 6, and month 3. Safety outcomes included adverse events (AEs) and ophthalmic assessments.

RESULTS:

Mean IOP reduction from baseline over the 6 time points ranged from 6.6 to 8.4 mmHg for the FE implant group, from 6.6 to 8.5 mmHg for the SE implant group, and from 6.5 to 7.7 mmHg for the timolol group. The primary efficacy end point was met; the upper limit of the 95% confidence interval of the difference between the implant groups and the timolol group was < 1 mmHg at all 6 time points. Study eye AEs, most of mild or moderate severity, were reported in 21.5%, 27.2%, and 10.8% of patients in the FE implant, SE implant, and timolol groups, respectively. The most common AEs included iritis (FE implant, 0.5%; SE implant, 5.1%), ocular hyperemia (FE implant, 3.0%; SE implant, 2.6%), reduced visual acuity (FE implant, 1.0%; SE implant, 4.1%; timolol, 0.5%), and IOP increased (FE implant, 3.5%; SE implant, 2.6%; timolol, 2.1%). One serious study eye AE occurred (endophthalmitis).

CONCLUSIONS:

The travoprost intraocular implant demonstrated robust IOP reduction over the 3-month primary efficacy evaluation period after a single administration. The IOP-lowering efficacy in both implant groups was statistically and clinically noninferior to that in the timolol group, with a favorable safety profile. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.