Your browser doesn't support javascript.
loading
Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function.
Leal-Vega, Luis; Piñero, David P; Molina-Martín, Ainhoa; Hernández-Rodríguez, Carlos J; Cuadrado-Asensio, Rubén; Martín-Gutiérrez, Adrián; Arenillas Lara, Juan Francisco; Coco Martín, María Begoña.
Afiliação
  • Leal-Vega L; Group of Applied Clinical Neurosciences, Department of Medicine, Dermatology and Toxicology, University of Valladolid, Valladolid, Spain.
  • Piñero DP; Group of Applied Clinical Neurosciences, Department of Medicine, Dermatology and Toxicology, University of Valladolid, Valladolid, Spain.
  • Molina-Martín A; Clinical Optometry Unit, Department of Ophthalmology, Hospital Vithas Medimar International, Alicante, Spain.
  • Hernández-Rodríguez CJ; Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
  • Cuadrado-Asensio R; Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
  • Martín-Gutiérrez A; Clinical Optometry Unit. Department of Ophthalmology, Centro Médico Virgen de la Caridad Hospital, Cartagena, España.
  • Arenillas Lara JF; Institute of Applied Ophthalmobiology, University of Valladolid, Valladolid, Spain.
  • Coco Martín MB; Group of Applied Clinical Neurosciences, Department of Medicine, Dermatology and Toxicology, University of Valladolid, Valladolid, Spain.
Semin Ophthalmol ; 39(5): 394-399, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38426308
ABSTRACT

PURPOSE:

To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults.

METHODS:

Pilot study enrolling 10 individuals (3 men, 7 women, mean age 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.

RESULTS:

Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (p = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (p = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain.

CONCLUSION:

Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Visão Binocular / Acuidade Visual / Realidade Virtual / Acomodação Ocular Limite: Adult / Female / Humans / Male Idioma: En Revista: Semin Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Visão Binocular / Acuidade Visual / Realidade Virtual / Acomodação Ocular Limite: Adult / Female / Humans / Male Idioma: En Revista: Semin Ophthalmol Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Espanha