Your browser doesn't support javascript.
loading
Cochlear measurement in computed tomography and magnetic resonance imaging data sets by the Otoplan measurement tool: a retrospective comparative study.
Otte, Martin Sylvester; Mueller, Verena; Burkhardt, Pauline; Endler, Christoph Hans-Juergen; Klussmann, Jens Peter; Luers, Jan Christoffer; Grosheva, Maria; Lang-Roth, Ruth.
Afiliação
  • Otte MS; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Mueller V; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Burkhardt P; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Endler CH; Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany.
  • Klussmann JP; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Luers JC; Center for Molecular Medicine Cologne, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Grosheva M; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
  • Lang-Roth R; Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
J Laryngol Otol ; : 1-5, 2024 Feb 19.
Article em En | MEDLINE | ID: mdl-38449092
ABSTRACT

BACKGROUND:

Using Otoplan software, it is possible to measure the cochlea before cochlear implant surgery. Until now, computed tomography (CT) of the cochlea has been necessary for this purpose. The aim of this study was to find out whether measuring the cochlea with magnetic resonance imaging (MRI) using Otoplan is possible with the same accuracy.

METHODS:

The cochlea of 44 patients of the local cochlear implant centre was measured by Otoplan using high-resolution CT-bone and MRI images, and the determined lengths were compared.

RESULTS:

No significant difference was found between the cochlear lengths measured, regardless of whether the length measurement was based on a CT or an MRI data set.

CONCLUSION:

For the determination of cochlear length prior to cochlear implant surgery, MRI images are just as suitable as CT images, therefore CT is not mandatory for length measurement by Otoplan, which could reduce the patient's radiation exposure.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Laryngol Otol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Laryngol Otol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Reino Unido