Your browser doesn't support javascript.
loading
Calixarenes and cyclodextrins as off- and on-fluorescence probes for carbazole.
Carranza, Matías E; Elero, Hugo M; Hernández, Pedro J Peña; Veglia, Alicia V.
Afiliação
  • Carranza ME; Universidad Nacional de Córdoba, Facultad de Ciencias Químicas, Departamento de Química Orgánica. Haya de la Torre y Medina Allende s/n, X5000HUA, Ciudad Universitaria, Córdoba, Argentina.
  • Elero HM; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), INFIQC, Córdoba, Argentina.
  • Hernández PJP; Universidad Nacional de Córdoba, Facultad de Ciencias Químicas, Departamento de Química Orgánica. Haya de la Torre y Medina Allende s/n, X5000HUA, Ciudad Universitaria, Córdoba, Argentina.
  • Veglia AV; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), INFIQC, Córdoba, Argentina.
Methods Appl Fluoresc ; 12(2)2024 Mar 21.
Article em En | MEDLINE | ID: mdl-38467069
ABSTRACT
Absorption and fluorescence spectra of the nitrogen polycyclic aromatic hydrocarbon carbazole (CZL) were analyzed with native cyclodextrins (CD;α,ß,γ); derivatizedCD(hydroxypropyl-ß-cyclodextrin,HPCD; methyl-ß-cyclodextrin,MeCD) and p-sulfonated calixarenes (SCAn, with n = 6 and 8) macrocycles. The results showed a slight increase in the absorbance ofCZLwithCD, but the mixture ofCZLwithSCAshowed lower absorption than the sum of the individual spectra. Also, changes in fluorescence were observed by adding the macrocycles, quenching withSCA, and significant increases withCD. The higher fluorescence enhancement was withHPCDrationalized as a complex formation with 11 stoichiometry, with an average value for the association constant (KA) of (12 ± 1) x 102M-1, and a quantum yield ratio between the complexedCZLand freeCZL(ΦCZL-HPCD/ΦCZL) of (1.56 ± 0.02) at neutral pH and 25.0 °C. These increases in fluorescence were used as an on-fluorescence switch to develop a supramolecular analytical method forCZLin aqueous samples. The best analytical parameters were inHPCD(LOD = 1.41 ± 0.01 ng mL-1). The method was validated in aqueous samples of river and tap water with recoveries between 96%-104%. The proposed supramolecular method is quick, direct, selective and represents an alternative and low-cost analysis method.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Methods Appl Fluoresc Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Methods Appl Fluoresc Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido