Your browser doesn't support javascript.
loading
Ratiometric fluoroprobe based on Eu-MOF@Tb3+ for detecting tetracycline hydrochloride in freshwater fish and its application in rapid visual detection.
Chen, Longtian; Li, Zhongjie; Dou, Yuemao; Wang, Huili; Chen, Chunyang; Wang, Xuedong.
Afiliação
  • Chen L; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China.
  • Li Z; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China.
  • Dou Y; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China.
  • Wang H; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China.
  • Chen C; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China. Electronic address: ccygroup@163.com.
  • Wang X; Jiangsu Key Laboratory of Environmental Science and Engineering, School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China. Electronic address: zjuwxd@163.com.
J Hazard Mater ; 469: 134045, 2024 May 05.
Article em En | MEDLINE | ID: mdl-38492388
ABSTRACT
Tetracycline hydrochloride (TCH), a prevalent antibiotic in aquaculture for treating bacterial infections, poses challenges for on-site detection. This study employed the reversed-phase microemulsion method to synthesize a uniform nano metal-organic framework (MOF) material, europium-benzene-p-dicarboxylic acid (Eu-BDC), doped with Tb3+ to form a dual-emission fluorescence probe. By leveraging the combined a-photoinduced electron-transfer (a-PET) and inner filter effect (IFE) mechanisms, high-sensitivity TCH detection in Carassius auratus and Ruditapes philippinarum was achieved. The detection range for TCH is 0.380-75 µM, with a low limit of detection (LOD) at 0.115 µM. Upon TCH binding, Eu-BDC fluorescence rapidly decreased, while Tb3+ fluorescence remained constant, establishing a ratiometric fluorescence change. Investigation into the TCH quenching mechanism on Eu-BDC was conducted using time-dependent density functional theory (TD-DFT) calculations and fluorescence quenching kinetic equations, suggesting a mixed quenching mechanism. Furthermore, a novel photoelectric conversion fluorescence detection device (FL-2) was developed and evaluated in conjunction with high-performance liquid chromatography-diode-array detection (HPLC-DAD). This is the first dedicated fluorescence device for TCH detection, showcasing superior photoelectric conversion performance and stability that reduces experimental errors associated with smartphone photography methods, presenting a promising avenue for on-site rapid TCH detection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetraciclina / Estruturas Metalorgânicas Limite: Animals Idioma: En Revista: J Hazard Mater / J. hazard. mater / Journal of hazardous materials Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tetraciclina / Estruturas Metalorgânicas Limite: Animals Idioma: En Revista: J Hazard Mater / J. hazard. mater / Journal of hazardous materials Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda