ABSTRACT
This study investigates the feasibility of estimating the radioactivity of radiopharmaceuticals using shielded syringes. The radioactivities of 99mTc-MDP, 99mTc-HMDP, 99mTc-ECD, 99mTc-MAG3, and 123I-IMP were measured using a dose calibrator. Correlation coefficients and regression equations were obtained from the radioactivity in the shielded and unshielded syringes. 99mTc-MDP was also measured for residual radioactivity after the administration. The correlation coefficients of 99mTc-MDP, 99mTc-HMDP, 99mTc-ECD, 99mTc-MAG3, and 123I-IMP were rs = 0.9998, rs = 0.9997, rs = 0.9999, rs = 0.9998, and rs = 0.9888, respectively. The regression equations were y = 0.0364x + 0.0913, y = 0.0349x + 0.0273, y = 0.0343x - 0.0018, y = 0.0522x + 0.1215, and y = 0.0383x + 0.0058, respectively. The correlation coefficient for the residual radioactivity of 99mTc-MDP was rs = 0.9887 and the regression equation was y = 0.1505x + 0.0853. The radioactivity of 99mTc- and 123I-labeled radiopharmaceuticals in shielded syringes was accurately measured. It was suggested that the measuring shielded syringes could provide an estimate of the actual radioactivity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Seringas / Estudos de Viabilidade / Tecnécio / Compostos Radiofarmacêuticos / Radioisótopos do Iodo Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Seringas / Estudos de Viabilidade / Tecnécio / Compostos Radiofarmacêuticos / Radioisótopos do Iodo Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Japão