Your browser doesn't support javascript.
loading
Circuital modelling in muscle tissue impedance measurements.
Clemente, Fabrizio; Amato, Francesco; Adamo, Sarah; Russo, Michela; Angelone, Francesca; Ponsiglione, Alfonso Maria; Romano, Maria.
Afiliação
  • Clemente F; Institute of Crystallography, Italian National Research Council, Italy.
  • Amato F; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
  • Adamo S; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
  • Russo M; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
  • Angelone F; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
  • Ponsiglione AM; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
  • Romano M; Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125, Naples, Italy.
Heliyon ; 10(7): e28723, 2024 Apr 15.
Article em En | MEDLINE | ID: mdl-38596118
ABSTRACT
Electrical impedance spectroscopy (EIS) stands as a widely employed characterization technique for studying muscular tissue in both physio/pathological conditions. This methodology commonly involves modeling tissues through equivalent electrical circuits, facilitating a correlation between electrical parameters and physiological properties. Within existing literature, diverse equivalent electrical circuits have been proposed, varying in complexity and fitting properties. However, to date, none have definitively proven to be the most suiTable for tissue impedance measurements. This study aims to outline a systematic methodology for EIS measurements and to compare the performances of three widely used electrical circuits in characterizing both physiological and pathological muscle tissue conditions. Results highlight that, for optimal fitting with electrical parameters relevant to tissue characterization, the choice of the circuit to be fitted closely hinges on the specific measurement objectives, including measurement parameters and associated physiological features. Naturally, this necessitates a balance between simplicity and fitting accuracy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália País de publicação: Reino Unido