Your browser doesn't support javascript.
loading
Detection of pit and fissure sealant microleakage using quantitative light-induced fluorescence technology: an in vitro study.
Nam, Sang-Mi; Ku, Hye-Min; Lee, Eun-Song; Kim, Baek-Il.
Afiliação
  • Nam SM; Department of Dental Hygiene, SahmYook Health University, Seoul, Republic of Korea.
  • Ku HM; Department of Preventive Dentistry & Public Oral Health, BK21 FOUR Project, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, Republic of Korea.
  • Lee ES; Department of Preventive Dentistry & Public Oral Health, BK21 FOUR Project, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, Republic of Korea.
  • Kim BI; Department of Preventive Dentistry & Public Oral Health, BK21 FOUR Project, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 120-749, Republic of Korea. drkbi@yuhs.ac.
Sci Rep ; 14(1): 9066, 2024 04 20.
Article em En | MEDLINE | ID: mdl-38643213
ABSTRACT
This in vitro study aimed to evaluate the feasibility of quantitative light-induced fluorescence (QLF) technology for detecting the presence and severity of microleakage of pit and fissure sealants. The areas of interest (AOIs) were 160 pits and fissures of 40 extracted permanent teeth. Fluorescent images were acquired using a QLF device, and the maximum fluorescence loss ΔFmax of each AOI was analyzed. After staining and cross-sectioning of the teeth, histological dye penetration was scored on a scale of 0 to 3. The relationship between ΔFmax and microleakage depth was analyzed, and the areas under the curve (AUCs) were calculated. The │ΔFmax│ increased as microleakage depth increased. The ΔFmax values of microleakage areas showed a strong significant correlation with the histological scores of dye penetration (r = - 0.72, P = 0.001). AUC analysis showed a high diagnostic accuracy for microleakage depth (AUC = 0.83-0.91). The highest AUC of 0.91 was found when differentiating the outer half microleakage of the sealant (histological score 0 vs. 1-3). QLF technology is effective in assessing the presence and severity of microleakage, suggesting its potential for noninvasive detection and monitoring of sealant microleakage in clinical settings.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Selantes de Fossas e Fissuras / Fluorescência Quantitativa Induzida por Luz Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Selantes de Fossas e Fissuras / Fluorescência Quantitativa Induzida por Luz Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido