Your browser doesn't support javascript.
loading
Anatomical total shoulder arthroplasty revision to reverse shoulder arthroplasty using convertible glenoid: a systematic review of clinical and radiological outcomes.
Ranieri, Riccardo; Anzillotti, Giuseppe; Rose, Giacomo Delle; Borroni, Mario; Garofalo, Raffaele; Castagna, Alessandro.
Afiliação
  • Ranieri R; Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4 Pieve Emanuele, 20072, Milan, Italy. dr.riccardoranieri@gmail.com.
  • Anzillotti G; Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4 Pieve Emanuele, 20072, Milan, Italy.
  • Rose GD; Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy.
  • Borroni M; Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy.
  • Garofalo R; Shoulder and Sport Medicine Unit, Miulli Hospital, Strada Prov. 127 Acquaviva - Santeramo Km, 4, 100 Acquaviva Delle Fonti, 70021, Bari, Italy.
  • Castagna A; Shoulder and Elbow Unit, IRCCS Humanitas Research Hospital, via Manzoni 56 Rozzano, 20089, Milan, Italy.
Int Orthop ; 48(9): 2411-2419, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38656616
ABSTRACT

PURPOSE:

The aim of the present systematic review is to collect all the available evidence regarding the clinical and radiological results of revision to reverse shoulder arthroplasty (RSA) of modular anatomic shoulder prostheses (TSA) using a convertible metal-backed glenoid (MBG).

METHODS:

This study was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Studies investigating revision of TSA to RSA utilizing a convertible MBG and reporting clinical and radiological outcomes were identified.

RESULTS:

A total of five studies on the use of convertible modular glenoid component in the setting of TSA revision to RSA were finally included in the present systematic review. A total of 60 procedures were reported. Mean operative times was 65 min. Intraoperative complications included 3 cases of glenoid loosening. Only one case of dislocation was reported as postoperative complication. At mean follow-up of 32.3 months post-revision, no glenoid loosening was reported, VAS score decreased from 7.7 to 1.5, Constant Score increased from 24.8 to 57.6.

CONCLUSIONS:

Revision to RSA after failed TSA using a convertible modular glenoid component was associated with a low rate of intraoperative and postoperative complications, low surgical time and led to good results in term of pain relieve and functional outcomes. Given the complexity and risk associated with revision of anatomic shoulder prosthesis having a convertible glenoid may help to simplify the procedure and improve clinical results.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Articulação do Ombro / Artroplastia do Ombro / Prótese de Ombro Limite: Humans Idioma: En Revista: Int Orthop Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Articulação do Ombro / Artroplastia do Ombro / Prótese de Ombro Limite: Humans Idioma: En Revista: Int Orthop Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha