Your browser doesn't support javascript.
loading
NiFe-LDH/nylon 6 composite electrospun on polypropylene membrane: A new extractive device development for porous membrane protected micro-solid-phase extraction of organophosphate pesticides from fresh fruit juice samples coupled with liquid chromatography tandem mass analysis.
Shirkhodaie, Mahsa; Seidi, Shahram; Shemirani, Farzaneh; Moghadasian, Sepideh.
Afiliação
  • Shirkhodaie M; School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran.
  • Seidi S; Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran. Electronic addre
  • Shemirani F; School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran. Electronic address: fashemirani@ut.ac.ir.
  • Moghadasian S; Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, 15418-49611 Tehran, Iran.
Food Chem ; 451: 139368, 2024 Sep 01.
Article em En | MEDLINE | ID: mdl-38657518
ABSTRACT
A unique strategy for developing porous membrane protected micro-solid phase extraction has been provided. An electrospun composite was fabricated on the sheet of membrane. To this end, NiFe-layered double hydroxide/Nylon 6 composite nanofibers were coated on a polypropylene membrane sheet followed by folding into a pocket shape, which were then utilized as a novel extractive device to extract of organophosphorus pesticides from fresh fruit juice samples prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. The fabricated hybrid composites were successfully characterized. The effective parameters on extraction performance were investigated. LODs were 0.020-0.065 ng mL-1. Excellent linearity (R2≥0.996) was observed between 0.05 and 100.0 ng mL-1. RSDs% were in the range of 3.1-5.8% (intra-day, n = 3) and 2.6-5.5% (inter-day, n = 3×3). Satisfactory related recovery values within the acceptable range of 90.7-111.2% with RSDs% below 6.7% were achieved for the analysis of real samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Polipropilenos / Caprolactama / Espectrometria de Massas em Tandem / Microextração em Fase Sólida / Sucos de Frutas e Vegetais Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Polipropilenos / Caprolactama / Espectrometria de Massas em Tandem / Microextração em Fase Sólida / Sucos de Frutas e Vegetais Idioma: En Revista: Food Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Irã