Your browser doesn't support javascript.
loading
Removal of Methylene Blue Dye from Aqueous Solutions Using Polymer Inclusion Membrane Containing Calix[4]pyrrole.
Nowik-Zajac, Anna; Zawierucha, Iwona; Lagiewka, Jakub; Jaksender, Karolina; Witt, Katarzyna; Malina, Grzegorz; Sabadash, Vira.
Afiliação
  • Nowik-Zajac A; Institute of Chemistry, Jan Dlugosz University in Czestochowa, Armii Krajowej 13/15, PL 42200 Czestochowa, Poland.
  • Zawierucha I; Institute of Chemistry, Jan Dlugosz University in Czestochowa, Armii Krajowej 13/15, PL 42200 Czestochowa, Poland.
  • Lagiewka J; Institute of Chemistry, Jan Dlugosz University in Czestochowa, Armii Krajowej 13/15, PL 42200 Czestochowa, Poland.
  • Jaksender K; Institute of Chemistry, Jan Dlugosz University in Czestochowa, Armii Krajowej 13/15, PL 42200 Czestochowa, Poland.
  • Witt K; Faculty of Chemical Technology and Engineering, Bydgoszcz University of Science and Technology, Seminaryjna 3, PL 85326 Bydgoszcz, Poland.
  • Malina G; Department of Hydrogeology and Engineering Geology, AGH University of Krakow, Mickiewicza 30, PL 30059 Cracow, Poland.
  • Sabadash V; Department of Ecology and Sustainable Environmental Management, Lviv Polytechnic National University, UK 79000 Lviv, Ukraine.
Membranes (Basel) ; 14(4)2024 Apr 17.
Article em En | MEDLINE | ID: mdl-38668120
ABSTRACT
The effective purification of aqueous solutions of methylene blue dye was tested using polymer inclusion membranes (PIMs) that contained cellulose triacetate (CTA) as a polymer base, o-nitrophenyl octyl ether (o-NPOE) as a plasticizer, and meso-tetra methyl tetrakis-[methyl-2-(4-acetlphenoxy)] calix[4]pyrrole (KP) as a carrier. Scanning electron microscopy (SEM), thermogravimetric analysis (TGA), and attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy were used to define the microstructure and surface of PIMs. Experimental results showed that, with an increased concentration of methylene blue in an aqueous solution, the removal percentage also increased. Further observation showed that the flux increased with the rise in the source phase pH values from 3 to 10. The carrier and plasticizer content in the membrane significantly influenced the membrane's transport properties. The optimal composition of the membrane in percent by weight for KP was 74% plasticizer; 18% support, and 8% carrier. The maximum MB removal (93.10%) was achieved at 0.10 M HCl solution as the receiving phase. It was shown that the membrane with optimal composition showed good reusability and enabled the easy and spontaneous separation of methylene blue from aqueous solutions.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Membranes (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Membranes (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Polônia País de publicação: Suíça