Your browser doesn't support javascript.
loading
Development of a Time Projection Chamber Readout with Hybrid Pixel Sensors for Beam Monitoring.
Song, Yingdong; Yang, Haibo; Zhang, Yuezhao; Liao, Jianwei; Jia, Yanhao; Ma, Peng; Hou, Yufeng; Sun, Xiangming; Wang, Hulin; Song, Haisheng; Zhao, Chengxin.
Afiliação
  • Song Y; College of Physics and Electronic Engineering, Northwest Normal University, Lanzhou 730070, China.
  • Yang H; Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
  • Zhang Y; Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516003, China.
  • Liao J; Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
  • Jia Y; Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516003, China.
  • Ma P; School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Hou Y; Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
  • Sun X; Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
  • Wang H; Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516003, China.
  • Song H; School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
  • Zhao C; Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China.
Sensors (Basel) ; 24(8)2024 Apr 09.
Article em En | MEDLINE | ID: mdl-38676004
ABSTRACT
To monitor the position and profile of therapeutic carbon beams in real-time, in this paper, we proposed a system called HiBeam-T. The HiBeam-T is a time projection chamber (TPC) with forty Topmetal-II- CMOS pixel sensors as its readout. Each Topmetal-II- has 72 × 72 pixels with the size of 83 µm × 83 µm. The detector consists of the charge drift region and the charge collection area. The readout electronics comprise three Readout Control Modules and one Clock Synchronization Module. This Hibeam-T has a sensitive area of 20 × 20 cm and can acquire the center of the incident beams. The test with a continuous 80.55 MeV/u 12C6+ beam shows that the measurement resolution to the beam center could reach 6.45 µm for unsaturated beam projections.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Suíça